background image

Model: TC-135

Steambath Control

WARNING: 

Elderly persons, pregnant women, or those suffering from heart disease, high blood 

pressure, diabetes, or who are otherwise not in good health, do not use this device unless directed 

to do so by a physician. Also, do not use steambath while under the influence of alcohol.

!

06/07

Pub. No. 554- E

C

US

®

LISTED 995C

Installation and Operating Instructions

IMPORTANT: 

This control must be installed inside the 

steam room for proper operation of the system.

Temperature  Display:

  Indicates  steam  room  or  set 

point temperature.

Start/Stop Key Pad:

 Press key pad and generator will 

begin producing steam in a few minutes. The generator 

will  remain  on  for  30  minutes  when  used  with  the 

models  SM-46,  SM-79,  SM-4,  SM-5,  SM-7,  or  SM-8 

steam generators and 60 minutes for larger generators. 

Pressing the key pad a second time will stop the Steam 

Generator.

Heat Icon: 

Indicates the generator is producing steam 

when illuminated. The heater in the generator and the 

heat  icon  will  cycle  on  and  off  as  the  temperature  is 

maintained automatically in the steam room.

Temperature icon: 

Indicates the set temperature has 

been  reached  and  the  heater  in  the  generator  is  off. 

This icon will cycle on and off opposite that of the heat 

icon.

Set  Temperature  Key  Pad: 

Press  to  display  the  set 

point.

Up/Down Key Pads: 

Press to adjust the temperature 

set point.

Cleaning Instructions:

 Use a damp cloth and mild soap. 

Do  NOT  use  abrasive  cleaners  which  might  scratch  the 

surface or the base of the control.

- 1 -

Control Features

Installation Instructions

The  TC-135  control  must  be  installed  inside  the 

steam  room.    For  convenience  the  recommended 

height from the floor is four feet. Provide a 1½” hole in 

the wall at this location (see Figure 1).

IMPORTANT: 

Multi-conductor  cable  must  be 

installed so that the end will not be buried inside the 

wall.  The  unit  will  not  operate  unless  the  control  is 

1. Pre-Installation - Control Location

a)

Remove  the  multi-conductor  cable  from  the  control 

packing  box.  Carefully  route  the  multi-conductor 

control  cable  from  the  Steambath  Generator  to  the 

TC-135 located inside the steamroom (see Figure 2).  

Route multi-conductor cable though a ¾” conduit to 

protect  the  cable  from  damage  and  to  facilitate 

replacement if necessary.

2. Electrical Rough-in

a)

1.

2.

3.

4.

5.

6.

TC-135

Digital Temperature Control

TEMP CONTROL

SET

TEMP

START

STOP

5

6

2

4

3

IMPORTANT: 

the TC-135 Control will only function with one of the following Steamist Generator models: SM-46, 

SM-79, SM-4, SM-5, SM-7, SM-8, SM-11, SM-12, SM-15, System-18, System-24, System-30.

1½“ Hole

located four feet

from the floor

Double-sided

Adhesive Pad

TC-135 Digital

Temperature Control

Figure 1

IMPORTANT: 

Run  the 

Control Cable through 

a ¾” conduit.

Coupler

1

Reviews: