Model: TC-135
Steambath Control
WARNING:
Elderly persons, pregnant women, or those suffering from heart disease, high blood
pressure, diabetes, or who are otherwise not in good health, do not use this device unless directed
to do so by a physician. Also, do not use steambath while under the influence of alcohol.
!
06/07
Pub. No. 554- E
C
US
®
LISTED 995C
Installation and Operating Instructions
IMPORTANT:
This control must be installed inside the
steam room for proper operation of the system.
Temperature Display:
Indicates steam room or set
point temperature.
Start/Stop Key Pad:
Press key pad and generator will
begin producing steam in a few minutes. The generator
will remain on for 30 minutes when used with the
models SM-46, SM-79, SM-4, SM-5, SM-7, or SM-8
steam generators and 60 minutes for larger generators.
Pressing the key pad a second time will stop the Steam
Generator.
Heat Icon:
Indicates the generator is producing steam
when illuminated. The heater in the generator and the
heat icon will cycle on and off as the temperature is
maintained automatically in the steam room.
Temperature icon:
Indicates the set temperature has
been reached and the heater in the generator is off.
This icon will cycle on and off opposite that of the heat
icon.
Set Temperature Key Pad:
Press to display the set
point.
Up/Down Key Pads:
Press to adjust the temperature
set point.
Cleaning Instructions:
Use a damp cloth and mild soap.
Do NOT use abrasive cleaners which might scratch the
surface or the base of the control.
- 1 -
Control Features
Installation Instructions
The TC-135 control must be installed inside the
steam room. For convenience the recommended
height from the floor is four feet. Provide a 1½” hole in
the wall at this location (see Figure 1).
IMPORTANT:
Multi-conductor cable must be
installed so that the end will not be buried inside the
wall. The unit will not operate unless the control is
1. Pre-Installation - Control Location
a)
Remove the multi-conductor cable from the control
packing box. Carefully route the multi-conductor
control cable from the Steambath Generator to the
TC-135 located inside the steamroom (see Figure 2).
Route multi-conductor cable though a ¾” conduit to
protect the cable from damage and to facilitate
replacement if necessary.
2. Electrical Rough-in
a)
1.
2.
3.
4.
5.
6.
TC-135
Digital Temperature Control
TEMP CONTROL
SET
TEMP
START
STOP
5
6
2
4
3
IMPORTANT:
the TC-135 Control will only function with one of the following Steamist Generator models: SM-46,
SM-79, SM-4, SM-5, SM-7, SM-8, SM-11, SM-12, SM-15, System-18, System-24, System-30.
1½“ Hole
located four feet
from the floor
Double-sided
Adhesive Pad
TC-135 Digital
Temperature Control
Figure 1
IMPORTANT:
Run the
Control Cable through
a ¾” conduit.
Coupler