ChromaSense Light Instructions
Model: TSCH
Figure 3
Figure 1
Figure 2
Figure 4
11/15
Pub. No. 322-B
- 1 -
Installation and Operating Instructions
C
US
®
NOTE: This device is not designed to work with the TSC-250.
ChromaSense Option:
The ChromaSense Light features a white light for general
lighting of the steam shower. The white light, neutral in color, is
equivalent to approximately a 50 watt down light. The Chroma-
Sense module may be connected to a non-powered light switch
to operate the white light from outside the steam room.
The ChromaSense Light system is designed to work with the
Steamist TotalSense TSG generators and with all versions of
the TSC Spa Controls. The white light will work independently
with just a non-powered light switch but the multicolored
ChromaSense Capability can only function with the TSC spa
control.
Although a single light should be adequate for most home
steam showers it is possible to gang multiple lights/modules
together for additional light. To gang multiple lights you will need
to connect the two or more light modules via control cable
connections. (figure 3)
Once they are joined by the cable, open up the covers to the
light boxes. Leave one set to master and set the others to
slave.(figure4)
ChromaSense Installation:
1. Select a location in the ceiling for the ChromaSense light
installation and make a 3-1/2” hole for the light in this location
(Figure 2).
2. Select a location to mount the TSCH module. The TSCH
module requires a 120V outlet nearby to power the light.
3. Route the light cable (25’ provided) from the TSCH module to
the hole for the light. Plug the cable into the TSCH module.
Plug the other end into the light and mount the light into the
ceiling, by folding the spring clips back while inserting it into
the mounting hole.
4. (Optional) Connect the auxiliary light switch terminals on the
TSCH module to a non-powered light switch located outside
the steam shower. This switch must not be connected to
power and the switch must be in a separate box from any
other light switches. For this connection, use any suitable low
voltage wire 18-24 gauge (Customer suppied)(Figure 6).
5. Connect the control cable (35’ provided) to the rest of the
Total Sense system.
6. Connect the 12 volt power supply to the TSCH module and
plug when the rest of the system has been installed.
7. After everything is fully tested apply silicone (provided)
around the fixture to seal it.
Diagnostics Lights (Figure 4):
1. The Red power LED will be lit whenever the power adapter is
plugged into the wall.
2. The green LED 2 will flash when it is communicating to the
TSC Spa Control.
3. LED 3 is not used.
®