- 1 -

Optional Auto

Drain Installed

Model TSG-AD

Water Inlet

" Compression

Fitting

¾" Safety 

Relief Valve

¾" Steam

Outlet

Electrical

Panel Cover

Knockouts for

Electrical 

Supply Line

Knockouts for
Control Cable

Install Upright

and Level

C

US

®

Model: TSG-12 & TSG-15

WARNING:

 

Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or 

who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use 
steambath while under the influence of alcohol. For additional Important Safety Information, please see a separate 
instruction sheet Pub. No. 199.

!

IMPORTANT:

 The warranty of this product is voided if it is used in a commercial application or for anything other than a residential 

steambath installation. All electrical connections must be performed by a licensed electrician in accordance with Local and National 
Electric Codes. 

This  product is not intended for use with Home Automation systems.

Electrical Installation Instructions

Steambath Generators

The Steamist “TSG” Generator operates with only “TSC” series 
controls mounted inside and an optional TSX or TSR remote 
control located outside the steamroom. It’s small enough in size 
to be tucked away using very little space in a vanity, closet, or 
basement, but large enough to provide steam for most residential 
baths.
The Steamist “TSG” Steambath Generator comes factory 
assembled, carefully wired and tested.

NOTE: 

A “TSC” series control is required to operate the "TSG" 

generator.

1. 

Pre-Installation

a) Proper electrical supply (208 or 240 Volt): See rating 

label on Steam Generator and Chart on page 4. 
Determine proper size of wire, voltage, amperage, and 
phase for the Steam Generator. 90°C copper wire is 
required for generator connection.

b) In-line fuse/circuit breaker required: Fuse/circuit breaker 

to be installed must be sized in accordance with chart 
on back page. Do NOT install a GFI (Ground Fault 
Interrupter) to this equipment (per article 210-8 in the 
National Electric Code).

c) Route power supply cable to the location where the 

Steam Generator will be installed (before walls are 
closed).

2.

 Electrical Rough-in

a) Route appropriate power cable to the location the Steam 

Generator will be installed. If receptacle is desired, 
mount the box for the receptacle near the location of  
the Steam Generator.

 

    

NOTE: 

The plug and receptacle require a rating of no 

less than 250V and proper amperage. Refer to chart on 
page 4 for amperage rating.

 

    After the walls are complete, the Steam Generator and 

Control can be wired.

3.

 

Steam Generator Electrical Installation

 WARNING: 

All power to the Steam Generator must be 

turned off. 

a) Remove the four screws holding the electrical access 

cover and remove cover.

b) Locate the supply line knockout. Mount proper strain 

relief into knockout hole.

c) Strip back power cable’s outer insulation jacket 

eight inches and insert into Steam Generator.  
Strip back insulation ½" from the three (3)     
incoming wires (two power and one ground). 

d) Insert ground wire into grounding lug located        

on the right side of the electrical compartment   
and secure.

 

CAUTION:

  Be sure the ground wire does not 

come in contact with a live electrical part.

 

e) Locate the terminal/fuse block in the upper portion        

of the electrical compartment. Insert power wires 
into the power lugs on the front of the terminal/fuse 
block and secure.

4. 

Optional Auto Drain Valve Connection

 

a) Open knockout for Auto Drain Valve conduit 

connection.

b) Route flexible conduit from valve to knockout and 

secure. 

c) Connect two wires from valve to the auto drain 

connection J8 on the printed circuit board (see 
Figure 2). 

Figure 1 - Steam Generator

®

Summary of Contents for TSG-12

Page 1: ...r 90 C copper wire is required for generator connection b In line fuse circuit breaker required Fuse circuit breaker to be installed must be sized in accordance with chart on back page Do NOT install a GFI Ground Fault Interrupter to this equipment per article 210 8 in the National Electric Code c Route power supply cable to the location where the Steam Generator will be installed before walls are...

Page 2: ...ected by using the sizing page in the Full Line Brochure Pricing Guide or The Generator Sizing Guide in the Residen tial Systems Steambath Product Information section of the Steamist website www steamist com CAUTION An improperly sized Steam Generator will NOT produce the amount of steam necessary to reach selected temperature The proper voltage Steam Generator has been selected i e 208V or 240V A...

Page 3: ...to an indirect waste or as required by local codes Connect to Hot or Cold water supply Auto Drain Ready Capped Line The Plumbing Instructions must be given to the homeowner for future use Shutoff Valve Keep in open position during normal operation STOP 2 1 2 1 TIME TEMP IM STOP TSX Auxilary Outside Control Union Required Generator 1 All 4 Switches to the left Factory Default Setting 1 2 3 4 1 2 3 ...

Page 4: ...208 240VAC Supply Connection 35A 35A L1 60A 60A L2 GND 0 8A 208 240VAC 208 240VAC 15VDC Model TSG 12 TSG 15 Figure 5 Wiring Diagram Electrical Installation Instructions 90 C copper wire is required for generator connection Installation shall be in accordance with NEC and local electrical codes Specification Chart Model No Max Cu Ft For Area Up To KW Volt Phase Amps Breaker Size TSG 12 TSG 15 550 6...

Reviews: