I N S T A L L A T I O N
17
Installation on wall (with mounting bracket – option MB)
1.
Optional Mounting bracket (option
MB
) is available to your steamOvap representative
in order to ease up wall mounting process.
2.
Verify that wall structure and strength is appropriate to support the operating weight of
the IER electric steam humidifier.
In case, the wall is not solid enough to support operating weight of
IER
electric steam
humidifier, install it on a floor stand (
FS
option is available to your steamOvap
representative).
3.
Mark the wall or support according to the above holes location, Drill holes to the wall or
support to attach the mounting bracket to the wall as per the size of anchors and/or
screws.
Distance between the 2 holes in Mounting bracket is 15in [381mm]
Figure 10 – Installation with Mounting bracket
4.
Use anchors of sufficient size (at least 1/4in [6mm]). Install the mounting bracket to the
wall or support.
Ensure that the mounting bracket is properly levelled.
5.
With front cover removed, hung the IER electric steam humidifier onto the mounting
bracket.
6.
Install the 2 supplied screws to avoid the IER humidifier to move up from the mounting
bracket.
Installation on Floor Stand (option FS)
1.
Ensure that the floor structure and strength is appropriate to support the operating
weight of the
IER
electric steam humidifier.
2.
Attach the floor stand to the floor or structure to avoid any movement of the
IER
electric steam humidifier.
You can use bolt or screws to attach this one to surrounding structure or to the floor.
3.
Install Humidifier (with front cover removed) on the floor stand and secure it with
supplied bolts.
4.
Re-install the front cover to the humidifier.
15in
[381m
m]