background image

 
Failure analysis 
PF166 

 

 

  Pfad \ Datei: 

I:\Projekte\SOLAR\PV-Entw\FREEZER\_E5970_KS-solar-LHG\14_Service\Failure analysis.doc 

Seite 3 von 5   

  Speicherdatum: 

 

Bearbeiter:   Gutzeit 

 

 

4.

 

Check inverter box

 (beside the compressor) 

[235]

 

 

The signal to start the compressor 

[230]

 will be activated by a short circuit between "C" and 

"T". There is no risk of high voltage, sparks or high current. You can use even a not isolated 
cable. If the thermostat-display-electronic 

[40] 

failed the compressor 

[230]

 could be started 

manually by a short circuit between "C" and "T" of the inverter box 

[235]

 

 

Before short circuiting the terminal "C" and "T" to start the compressor 

[230]

 manually please 

disconnect  all  connectors  coming  from  the  display-electronic 

[40]

.  First  brown  "+"  cable 

above "F" than the black "T" and blue "C" cable. If the inverter box 

[235] 

is connected to the 

battery  and  if  the  battery  voltage  is  higher  than  the  cut-off  voltage  the  compressor 

[230]

 

must start suddenly after disconnecting "C" and "T". 

 

If the compressor 

[230]

 do not start the inverter or the compressor 

[230]

 could be damaged 

Display
Electronik

Sensor

Compressor

 

5.

 

Compressor 

[230]

 

 

If you connect an LED to the "+" terminal above "F" 
and  to  the  "D"  terminal  (see  picture 2)  you  could 
have  a  feedback  if  the  inverter  box 

[235] 

is 

operating  and  some  other  events  are  responsible 
why the compressor 

[230]

 don't starts. See table. 

Compressor

 

6.

 

Electronic thermostat with user interface (display and key board) 

[40]

   

If the display 

[40]

 monitors no number or if the Minus-LED is not blinking please disconnect 

the blue cable "C" on the inverter box 

[235] 

as well as the other blue cable "-" and connect 

them  together.  If  the  display 

[40]

  will  not  show  any  characters  or  blinking  Minus-LED  the 

inverter box 

[235] 

is damage. 

 

 

Reviews: