Failure analysis 
PF166 

 

 

  Pfad \ Datei: 

I:\Projekte\SOLAR\PV-Entw\FREEZER\_E5970_KS-solar-LHG\14_Service\Failure analysis.doc 

Seite 4 von 5   

  Speicherdatum: 

 

Bearbeiter:   Gutzeit 

 

 

Display
Electronik

Sensor

Compressor

 

Failed Component 

Compressor [230] 

Display-Electronic [40] 

Integrated in opener 

LED between "+" and "D" 

Connected to inverter box 

Battery connector 
or fuse 
or broken battery cable 

Is not running 

Not running 
No blinking Minus LED 
No display 

Off 

Compressor 

If  the  compressor  doesn't  start 
after short circuiting "C" and "T" 
the  display-electronic  is  not 
responsible for the failure 

Blinking  LED  or  displaying 
character 

5 thermal cut out 
4 motor speed error 
3 motor start error 

Inverter box 

Compressor is not running 

Display could be out of order 

5 thermal cut out 

Inverter box 

Compressor is not running 

Electronic  is  connected  direct 
to  battery  by  connecting  "C" 
and  "-"  together  and  display  is 
monitoring anything 

Off  because  inverter  is  not 
supplied with energy 

Electronic 

Compressor is off  
or runs continuously 

No  display  even  after  testing 
step 6 

 

Sensor 

Running in safety operation 

Display "F4" 

 

7.

 

De-installation inverter box 

[235]

  

If you identify that the inverter box 

[235]

 is damaged you can uninstall the box. Therefore 

please disconnect all cables and open the screw.  
Than you can remove the inverter and disconnect the connector from the compressor 

 

 
8.

 

De-installation of display electronic 

[40]

 

 

First you had to open the 3 screws 

[60] 

at the bottom of the opener. 

 TORX T15 

 

unplug cables 
and open 
screw 

unplug 
connector 

cables leaves 
to top 