customerservice@focus-ontools.com
3
1-800-348-5004
SPECIFICATIONS
ASSEMBLY
1. During shipment, some Needles may fall out of the Needle Holder.
If so, remove the Needle Holder (26), Needles (25), and Spring (27)
from the Needle Tube (28).
2. You should have 19 Needles. If you are missing Needles, call FOT Tools.
If any of the Needles are bent, do not use them.
3. Insert the small ends of the Needles (25) into the holes in the Needle
Holder (26). The Needles should sit flush with the top of the Needle
Holder.
4. Slide the Spring (27) over the Needles (25).
5. Slide the Needle assembly into the Needle
Tube (28).
See Air Needle Scaler
Components on page 6.
6. Line up the Driver Retainer with the slit
in the Needle Tube (28). Insert the
Housing (20) into the Needle Tube (28).
See Figure A.
Stroke
1/2″
Blows per minute
4000
Overall Length
18″
Average Air Consumption 10 CFM @ 90 PSI
Air Inlet
1/4″ -18 NPT
Throttle
Housing
Air Inlet
Needle Tube
Needle Holder
Needles
Driver Retainer
Figure A
Housing (20)
Slit in Needle Tube (28)
Driver Retainer
: Needle Tube Assembly