Gasoline is extremely flammable and explosive under certain conditions.
Refuel in a well ventilated area with the engine stopped.
Keep away from lighted cigarette, fire and sparks when refueling the generator.
Always refuel in a well-ventilated location. Wipe up spilled gasoline at once.
Connections for standby power to a building's electrical system must be made
by a qualified electrician and must comply with all applicable laws and electrical
codes. Improper connections can allow electrical current from the generator
to back feed into the utility lines.
Such back feed may electrocute utility company works or other personel who
contact the lines during a power outage, and when utility power is restored, the
generator may explode, burn, or cause fire in the building's electrical system.
Always make a pre-operation inspection before you start the engine. You may prevent an
accident or equipment damage.
Place the generator at least 3ft away from buildings or other equipment during operation.
Operate the generator on a level surface. If the generator is tilted, fuel spillage may result.
Know how to stop the generator quickly and understand operation of all the controls.
Never permit anyone to operate the generator without reading and understanding the
instructions in this manual.
Keep children and pets away from the generator when it is in operation.
Keep away from rotating parts while the generator is running.
The generator is a potential source of electrical shocks when misused.
Do not operate the generator in the rain or snow and do not let it get wet.
Owner’s Manual
4
Do not operate with wet hands.
2.SAFETY LABEL LOCATIONS
2.1 Outside view
Fig.1 Outside view
Fuel level indicator
Air exhaust hole
Top cover
Air intake hole
Rear cover
Access door
Starter grip
Control panel
Fuel filler cap
Air intake hole
Front cover
LCD screen
Operation button
Side cover
3500W Digital Generator
5
2.2 Control pannel
Fig.2 Control panel
ON: Engine speed is kept at economical state automatically to minimize the fuel
consumption while in operation.
This position is recommended when the output power is less than 1 kW.
2.3 ECON switch
When high electrical load appliances are connected simultaneously, turn the ECON switch
to the OFF position to reduce voltage changes.
ECON switch system does not operate efficiently if the electrical appliance requires the
higher needed electric power.
OFF: ECON switch does not operate . Engine speed is kept over rated speed.
ON START OFF
ON ECON OFF
OPERATION
OVERLOAD
SHORT CIRCUIT
_
+
DC12V/8.3A
AC
0
Grounding terminal
Choke knob
Oil Alert Lamp
Fuel valve lever
Start switch
Econ switch
Operation indicator (green) Overload indicator (yellow)
Short circuit indicator (red)
DC terminal
AC receptacle
ON
OFF
OIL ALE RT
Owner’s Manual
6
2.4 LCD screen and operation button
Fig.3 LCD screen and operation button
LCD screen displays the AC/DC output state and the wattages of electrical load.
The AC/DC output is kept in OFF (no output) when the engine is started.
AC operation button switches the AC output between ON and OFF.
DC operation button switches the DC output between ON and OFF.
If the generator is overloaded, the overload indicator (yellow) will go ON.
If there is a short in the connected appliance, the AC/DC output will be shut off automatically
while the short circuit indicator (red) will be ON.
ALM operation button is used to reset the generator when short circuit occsion occurs.
Press the DISP operation button once, the LCD screen backlighting will remain ON for about 5
LCD screen back light
DC switch
AC switch
LCD screen
DISP
ALM
DC
AC
Alarm clear
3500W Digital Generator
7
seconds. It helps to operate in the dark.
Be sure to check the generator on a level surface with the engine stopped.