background image

1.Turn the access door knob left 1/4 turn, open the access door. Then remove the two side covers 

and the rear cover.

2. Unsnap the clips, remove the air cleaner cover.
3. Remove the sponge element from the air cleaner cover.

Wash the sponge element in a solution of household detergent and warm water, then rinse 
thoroughly, or wash in nonflammable or high flash point solvent. Allow the sponge element to 
dry thoroughly. Soak the sponge element in clean engine oil and squeeze out the excess oil. 
The engine will smoke during initial startup if too much oil is left in the sponge element. 
Reinstall the sponge element to the air cleaner cover.

4. Reinstall the air cleaner cover.
5. Reinstall the rear cover, two side covers and the access door in order.

7.4 Spark plug service

Recommended spark plug: WR7DC
To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.
1. Open the access door.
2. Remove the spark plug cap.
3. Use the wrench to remove the spark plug.
4. Clean any dirt from around the spark plug base.

Fig.16

Fig.17

Sponge element

Air cleaner cover

Spark plug wrench

Air cleaner base

Owner’s Manual

20

5. Visually inspect the spark plug.Discard it if the insulator is cracked or chipped.Clean the spark 

plug with a wire brush if it is to be reused.

6. Measure the plug gap with a feeler gauge.

The gap should be 0.02-0.03in. Correct as necessary by carefully bending the side electrode. 

Fig.18

7. Install the spark plug carefully by hand to avoid cross-threading.
8. After a new spark plug has been seated by hand,it should be tightened 1/2 turn with a wrench 

to compress its washer. If a used plug is being reinstalled, it should only required 1/8 to 1/4 turn
after being seated.

9. Reinstall the spark plug inspection cover and tighten the cover screw.
10. Close the access door.

Plug gap

The spark plug must be securely tightened. An improperly tightened spark plug can become 
very hot and possibly damage the generator.
Never use a spark plug with an improper heat range.

3500W Digital Generator

21

7.5 Spark arrester maintenance

If the generator has been running, the muffler will be very hot. Allow it to cool 
before proceeding.

Fig.19

The spark arrester must be serviced every 500 hours to maintain its efficiency.

1. Turn the access door knob left 1/4 turn, open the access door. Remove the 

two side covers and the rear cover.

2. Remove the spark arrester.
3. Use a brush to remove carbon deposits from the spark arrester screen.

Inspect the spark arrester screen for holes or tears. Replace if necessary.

4. Reinstall the spark arrester.
5. Reinstall the rear cover, two side covers and the access door in order.

Spark arrester

Owner’s Manual

22

8.TRANSPORTING/STORAGE

8.1 When transporting the generator, turn the fuel valve lever OFF and keep the generator level 

to prevent fuel spillage.

8.2 Before storing the unit for an extended period:

1. Be sure the storage area is free of excessive humidity and dust. 
2. Drain the fuel----

a. Open the access door.
b. Turn fuel valve to ON and then loosen the carburetor drain screw. Drain the gasoline from the 

carburetor and fuel tank into a suitable container.

c. Tighten the carburetor screw, close the fuel valve lever and access door.

3. Change the engine oil.
4. Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder. 

Crank the engine several revolutions to distribute the oil, then reinstall the spark plug.

5. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its

compression stroke and both the intake and exhaust valves are closed. 
Storing the engine in this position will help to protect it from internal corrosion.

Fig.20

Drain plug

3500W Digital Generator

23

Summary of Contents for SP-GG350D

Page 1: ...onsult an authorized dealer 3500W Digital Generator 1 Our generators are designed to give safe and dependable service if operated according to instructions Read and understand the Owner s Manual before operating the generator Failure to do so could result in personal injury or equipment damage CONTENTS 1 SAFETY INSTRUCTIONS 3 2 SAFETY LABEL LOCATIONS 5 3 PRE OPERATION CHECK 8 4 STARTING THE ENGINE...

Page 2: ...arter grip Control panel Fuel filler cap Air intake hole Front cover LCD screen Operation button Side cover 3500W Digital Generator 5 2 2 Control pannel Fig 2 Control panel ON Engine speed is kept at economical state automatically to minimize the fuel consumption while in operation This position is recommended when the output power is less than 1 kW 2 3 ECON switch When high electrical load applia...

Page 3: ... refueling tighten the fuel filler cap securely Fig 5 Oil surface E F Loosen Tighten 3500W Digital Generator 9 Gasoline containing alcohol If you decide to use a gasoline containing alcohol gasohol be sure its octance rating is at least as high as being recommended by us There are two types of gasohol one containing ethanol and the other containing methanol Do not use gasohol that contains more th...

Page 4: ...during a power outage and when utility power is restored the generator may explode burn or cause fires in the building s electrical system Limit operation requiring maximum power to 30 minutes For continuous operation do not exceed the rated power In either case the total wattage of all appliances connected must be considered Do not modify or use the generator for other purposes than it is intende...

Page 5: ...tal Generator 17 7 MAINTENANCE The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition Shut off the engine before performing any maintenance If the engine must be run make sure the area is well ventilated The exhaust contains poisonous gases Use our genuine parts or the equivalent The use of replacement parts which are not of equivalent quali...

Page 6: ...cover and tighten the cover screw 10 Close the access door Plug gap The spark plug must be securely tightened An improperly tightened spark plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range 3500W Digital Generator 21 7 5 Spark arrester maintenance If the generator has been running the muffler will be very hot Allow it to cool before proce...

Page 7: ...cuit Switch on the DC output Replace the DC circuit fuse Take the generator to an authorized dealer NO YES NO Is the operation indicator light ON Is the short circuit indicator light ON Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Take the generator to an authorized dealer Replace the electrical appliance or equipment Take the electrical ap...

Page 8: ...r 27 APG3104 28 BOLD Fuel tank 28 APG3104 29 BOLD Bolt 29 APG3104 30 BOLD Handle 30 APG3104 31 BOLD Bolt 31 APG3104 32 BOLD Sealing ring 32 APG3104 33 BOLD Start grip 33 APG3104 34 BOLD Bolt 34 APG3104 35 BOLD Ring cover 35 APG3104 36 BOLD Frame 36 APG3104 37 BOLD Bolt 37 APG3104 38 BOLD Fuel switch 38 APG3104 39 BOLD Oil alert lamp 39 APG3104 40 BOLD Engine switch 40 Owner s Manual 30 APA Part No...

Page 9: ...t costs if any must be paid by the purchaser If the purchaser does not receive satisfactory results form the Authorized Warranty Service Center the purchaser should contact Steele toll free 888 896 6881 THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned used as rental equipment or floor or display models Merchandise that has become damaged or inoperative because of ordinary wear misuse...

Reviews: