“THEBEN” Time Clock Setting Instructions Continued
Page 3 of 4
Document #1200608 Rev 3
02/25/2015
CLEARING ALL CHARGE (ON) AND CONTROL (OFF) CYCLES
1. To clear all existing program settings, press the "Menu" until "Program" is displayed. Press "OK". "NEW" will be
displayed. Press the "
◄
" or the "
►
" button until "DELETE" is displayed. Press "OK".
2. "SINGLE" will display. Use the "
◄
" or the "
►
" button until "DELETE ALL" is displayed. Press "OK" and "CONFIRM"
will display.
3. Press "OK" to confirm the clearing of all program settings or press the "MENU" button to escape and not clear any
program settings.
OVERRIDES
1. To temporarily override a current charge or control cycle, press and release the "
◄
" and the "
►
" buttons at the same
time. “OVERRI On" will appear and the clock will reverse the current program cycle. This override status will remain
until the next program cycle time, or it can be canceled by pressing and releasing the "
◄
" and the "
►
" buttons at the
same time again and "Off" will display.
2. The time clock can also be placed in a permanent ON (Charge) or permanent OFF (Control) status. To do so, press
and hold both the "
◄
" and the "
►
" buttons until "PERM On" or "PERM Off" is displayed. Follow the same procedure
to cancel the override.
FINAL
CHECKOUT
1. The heater(s) should reflect the program time.
a. During a charge (on) period the heater will display a “C”.
b. During a control (off) or peak period the heater will display a “P”.
2. The bars on the bar graph on the top side of the display indicate the charge (on) times. The numbers indicate time in
24 hour format (see Figure 1). The “ON’/”OFF” indicator will reflect the status of the contacts.
a. “OFF” displayed above the time indicates contacts 2 and 3 are closed (peak time).
b. “ON” displayed above the time indicates contacts 1 and 2 are closed (off peak or charge time).
c.
The relay only operates with line voltage applied.
Figure 3
1000 Series and 2000 Series Cord
Connected
Figure 2
EXT Series
FAN
RELAY
ELEMENT
RELAY
JUMPER
VIOLET
F3 T1 L1 L2
T2
F1 F2
WHITE
JUMPER JUMPER
YELLOW
BLUE
BLUE/WHITE
N
N
3
2
1
L
NOTE: Theben Time Clock should be mounted on a bracket. For EXT Series Order Item
#1040322 and for 1000/2000 Series Order Item #1040308.
BLUE
BLUE/WHITE
THERMOCOUPLE RED
OUTDOOR SENSOR
OUTDOOR SENSOR
ROOM SENSOR VIOLET
ROOM SENSOR VIOLET
THERMOCOUPLE YELLOW
1
L2
L1
T1
5
3
2
4
7
6
8
1 3
2
N
L