TV6.2
33
5 Commissioning
Example:
Peak current of the controller = 20A
1. Connection Instructions
Connect the device according to this manual (TV6.2)
Note:
Supply voltage
for TV6.2
max. 110V~, 160 V=
2. Commissioning
Basic connections: mains, tacho or armature voltage feedback, enable, com-
mand value
2.1 Enable switch:
open/enable voltage 0V
Command value voltage 0V, command value additional input: bridged to
GND.
Adjust switch S9 to tacho voltage, for armature voltage control adjust to 0.
Switch S4 in position 2, switch S5 in position 2
Adjust potentiometer I
max
to approx. 10%.
Potentiometer
Xp = to 50%
Potentiometer
ID
= 100%
Potentiometer
IxR = left full scale
Potentiometer
n
max
= left full scale
Potentiometer
INT = left full scale
Jumpers S6, S13, S14, and SW1(2-3), SW2 (2-3) are plugged.
2.2 Switching on the power
TV6
:
The LEDs 19-A (BTB), 19-D (stationary), 7-C (+15V), and 7-D (-15) must light.
All other LEDs do not light.