1. Place an O-ring seal in the notch of the line
connection.
2. Guide the threaded ring over the line
connection.
3. Turn the threaded ring clockwise until it is
hand-tight.
The line connections are fitted.
Connecting the lines
Prepare the following material (not contained in the package contents):
- Pressure line
- Suction line
- Assembly materials for the lines
To connect the lines to the pump and filter vessel as shown in illustration A at the start of this manual,
proceed as follows:
1. Lay the suction line from the pool to the pump.
Keep the suction line as short as possible. Longer lines reduce the pump output.
2. Lay the pressure line from the pump to the filter vessel.
The lines are connected.
Bleeding the pump
1. Establish the water flow to the pump. If necessary, open the shut-off valve or remove the plug in
the suction line.
2. Bleed the pump. To do so, undo the prefilter cover
1
.
The prefilter
11
fills with water.
3. Let the prefilter fill completely with water.
4. Close the prefilter cover.
5. Start up the pump.
6. Check the pump and the connections for leaks.
The pump is bled.
Operation
WARNING!
Risk of death when operating the water treatment system during bathing.
Hair or clothing might get sucked into the suction openings of the pool and in extreme cases
trap persons under water and prevent them from surfacing again.
-
Never operate water treatment system devices while persons are in the pool.
-
Prevent any access to the pool for as long as water treatment system devices are in use.
CAUTION!
Risk of injury!
A damaged device or damaged accessories may cause injuries.
-
Check the device and the accessories (see section "Testing").