Problem
Possible cause
Remedy
The pump is not running.
The timer is set.
Press the timer button. The running time
can be set when the pump is switched off.
Turn on the pump.
The external timer is set.
Check the running times on the external
timer.
If the problem cannot be solved, contact the customer service listed on the last page.
Technical data
Model:
SPS 175-1T
Flow rate:
max. 20,000 l/h (24.2
GPM)
Item number:
040090
Delivery head:
max. 15.0 m (49 ft.)
Pump function principle:
self-priming
Pool volume (water
content):
max. 61,000 l (10,000 gal)
Prefilter:
available
Water temperature:
max. 35 °C (95 °F)
Timer:
integrated timer
Connection diameter:
Ø 50 mm (2 in)
Battery for timer:
CR2032 button cell;
lithium 3V
Safety class:
IPX5
Power supply:
220-240 V~, 50 Hz
Insulation class:
F
Output:
max. 900 W
Sound pressure level ****:<70 dB(A)
**** Emission sound level comparable to a large household appliance