Rev. II.2017
Rev. II.2017
28
EN
DISPLAY MESSAGES BY NORMAL USE
message
stands for
note
weight over range
detect weight
weight below range
SETUP
User Setup
END
save and exit
OFF
power off
OVerLoaD
overload, exceeds 100% F.S. + 9e
2ND
2nd function
HOLD
scale is locked
UNSTaBle
load not stable
TARE
scale is tared
UNit KG
kg
UNit LB
lb
UNit USeR
User Unit
INVaLiD
invalid operation
ACCumulate
accumulate weight
no ACCumulate
no weight accumulated
NO DELete
no weight deleted
DELete
delete last weight
CLEAR
delete all weight
Password
Password mode
I. OPERATION
1) TURN ON THE SCALE
Press
for 1sec, to turn the scale on.
The scale performs initialization and boot-up testing, then the display flashes 3
times, and shows the max. capacity and the battery power. It will then detect, if
necessary, the weight hanging on the scale and Auto-Zero.
2) TURN OFF THE SCALE
Press
or for 1sec to turn the scale off
The scale displays the battery power and an off message (
), and turns off.
27
EN
REMOTE CONTROL
key
name
Correspondence with
main display key
function 1
function 2
Specifications
Zero
same as
zero scale
with , unit switch
increase digital
Tare
same as
tare in/out
with , tare set
right scroll digital
Hold
same as
lock/unlock
with , enter User Setup
confirm
Acc
a c c u m u l a t e
weight
with , switch resolution decrease digital
Del
delete last
weight
with , clear all weight
left scroll digital
F1
view accumu-
lated weight
with , view battery
power
View
NC
off
same as
lock/unlock
with , enter User Setup
confirm
2nd
same as
2nd function
with , enter Password
mode
exit and save