Rev. II.2017
Rev. II.2017
30
EN
You can then put the goods into the container to determine their own
weight.
CAUTION
Tare will reduce the apparent overloading range of the scale. For example, if a
5000*2kg scale has a 1000kg container as tare, the scale will overload at a new
weight of 4018kg (5000 – 1000 + additional 9 divisions of 2kg).
To quit the tare function (back to net mode), press
or
.
The
indicator lights off. Therefore, following criteria have to be fulfilled :
-The scale must not be locked, otherwise the scale will display
.
5) LOCK / UNLOCK (HOLD FUNCTION)
The lock function enables the scale to freeze the weight value at standstill. It sa-
ves the highest value measured, which is particularly interesting when the weight
value cannot be quickly determined or read by the user.
Press
or to lock the scale.
The indicator
lights on. Therefore, following criteria have to be fulfilled :
-The scale must be stable, otherwise the scale will display
TO QUIT THE LOCK FUNCTION, PRESS
OR .
The indicator
lights off.
6) ACCUMULATE
The accumulate function enables to measure the weight of a charge and to then
add another one to weight both charges together. This function can be combined
with the TARE function.
Therefore, following criteria have to be fulfilled:
-The scale must not be locked, otherwise, the scale will display
.
-The scale must be stable, otherwise, the scale will display
.
-The weight must exceed 0, otherwise, the scale will display
.
-The scale must return zero before new weight can be accumulated,
otherwise, the scale will display
.
Charge the scale and let it weight. When you´re done with weighing
the first load, press
, an charge the second load to determine the
total weight.
displays, indicating that the weight is accumu-
lated. The scale uses displayed weight, so gross or net weight is added
into the same accumulator.
29
EN
3) ZERO THE SCALE
Zeroing the scales is useful to define the zero value of the scale, which can lightly
vary depending on the environment temperature and due to light material fatigue.
Zeroing the scale before each use allows to guarantee best measurements results.
Press
or
to zero the scale.
The
indicator lights on to confirm that the scale is zeroed. Therefore, follow
-
ing criteria have to be fulfilled :
-No weight shall be hung on the scale
-The scale must not be locked, otherwise, the scale will display
-The scale must be stable, otherwise, the scale will display
-The scale must not be tared, otherwise, the scale will display
-The weight must be in Manual-Zero Range, otherwise, the scale will
display
For information about Manual-Zero Range, refer to the corresponding information
under “Scale configuration”
4) TARE FUNCTION
The tare function enables to weight goods packed in a container (gross mode)
subtracting the weight of the container itself. Therefore, you need to first weight
the container, and to then put the goods in it, so that the scale only determines
the weight of the goods (net weight).
To enter the tare function, press
or .
The
indicator lights on. Therefore, following criteria have to be fulfilled :
-The scale must not be locked, otherwise, the scale will display
-The scale must be stable, otherwise, the scale will display
-The weight must exceed 0, otherwise, the scale will display
-The weight must be lighter than 100% F.S., otherwise, the scale will
display
TARE SET
To define the weight of the container:
In gross mode, press
or . Then press
or to enter the Tare
Set mode.
The scale displays 00000, waiting for user input.
Press
or
, and
or
, input weight. Press
or
, enter
weight.
The
indicator lights on. Therefore, following criteria have to be fulfilled :
-The scale must be in gross mode, otherwise, the scale will display
-The weight must exceed 0, otherwise, the scale will display
.
-The weight must be lighter than 100% F.S., otherwise, the scale will
display .