Rev. II.2017
Rev. II.2017
MANUAL DE USUARIO
BALANZA DE GRÚA DE ALTA
RESOLUCIÓN
SBS-KW- 1000B | 1000R | 1000Y | 1000/10B
| ES |
41
EN
V.TROUBLESHOOTING
Possible Cause
Suggested Solution
discharged / defective battery check battery and charge
defective
key
press harder and keep
pressing 2sec
defective power cable
open front panel, check
power cable
defective mainboard
contact representative
not power-on
after
is
depressed
Problem
display flashes
discharged battery
charge battery
scale is disturbed
re-plug power cable
defective key
contact representative
no action
taken after key
pressed
load in motion
keep load stable
weak Anti-Motion
change Anti-Motion level
damped loadcell or mainboard dry loadcell or mainboard
defective mainboard
contact representative
weight reading
not stable
discharged battery
charge battery
load-cell stressed too long
hang scale in storage
drifting loadcell
contact representative
weight reading
not zero when
no load
scale not zeroed before
applying load
manual Zero scale before
loading
wrong unit
switch to correct unit
scale requires calibration
calibrate scale
defective loadcell or main-
board
contact representative
big error in
weight reading
defective charge board
defective battery
battery can
not be recharged
contact representative
discharged / defective remote
battery
replace remote controller
batteries
short remote
controlling
distance