1. OVERVIEW
The Steinberg Systems series of electronic price scales are equipped with
high precision load cell as primary instrument, the secondary instrument de
-
signed by using new technology and new materials such as 8951 single-chip
microprocessor as main chip and A/D converted with triple-integral.
The Steinberg Systems series of electronic price scale are good products with
reasonable prices. It has the functions of accumulation up to 99 times, over
-
load and under-voltage alarms, auto and continuous AC/DC shift, power sup
-
ply identification, auto temperature compensation, auto power-saving mode
without weights for 20 seconds and unit price storage and shift (8 different
prices can be saved for scale with 24 keys). Particularly, it can protect the
saved data to ensure accurate weighing.
2. FEATURES & SPECIFICATIONS
Model
3110 SBS-PW-60/5
3111 SBS-PW-100/10
Class
III
Precision
1/3000 F.S.
Rated capacity
60 kg
100 kg
Resolution (Standard)
6000
10000
Standard division (e)
5g
10g
Max capacity
60kg
100kg
Min capacity
200g
Zero range
0~60d
Tare range
0~60kg
0~100kg
Zero tracking range
0~5g
Limit display
60.090kg
100.090kg
NOTE:
e=d
2.3 ERROR RANGE
Weight
(described as e)
Error range
Outgoing inspection
Inspection after repair
0≤m≤500e
±0.5e
±1.0e
500e<m≤2000e
±1.0e
±2.0e
2000e<m≤3000e
±1.5e
±3.0e
3. ELECTRICAL CHARACTERISTICS
3.1 Working voltage: 230V(+10%~-15%); 50±2%Hz / 110V(+10%~-
15%); 60±2%Hz
Power consumption:
Not larger than 1VA, normal power consumption lower than 0.2VA
20
EN
21
3.2 Direct current characteristics
Storage battery capacity: 6V 4Ah
Rated voltage: DC6V
4. DISPLAY CHARACTERISTICS
4.1 Display windows
Weight window: 5 digits
Unit price window: 5 digits
Total amount window: 6 digits
WEIGHT (kg)
SBS-PW-
60/5
CLR
Clearing the unit price.
ZERO
The ZERO key zeroes the scale.
TARE
The TARE key subtracts tare values and changes the scale from gross
mode (no tare) to net mode.
ADD
Adding mode.
SAVE
Saving unit prices.
M1-M7 The M keys are used to store data (unit price value at 8 different
locations) in your scale.
0~9
The NUMERIC key (0~9) is used for setting unit price data.
•
DECIMAL POINT key is used for set the decimal position of unit price.
FUN
Backlight display switching on or off.
EN