Trouble
Instruction
Possible Reason
Remedy
AC lamp is not
glowing
Power may
not be con-
nected
•
The mains plug may
be disconnected
•
The power cable is
damaged
•
Insert the power
plug or replace it
if damaged
•
Change the pow-
er cable
Scale is not
turning on with
battery
There is no
DC power
supply to the
Scale
•
The storage batte-
ry is damaged
•
The battery con-
nection are not
proper
•
Replace the
battery of the
similar model
•
Ensure that con-
nections are in
good condition
Over voltage
LED glows,
Alarms and
automatically
turn off
Over Voltage
Battery is in use for too
long time
•
Charge the
battery
•
Change the
battery is found
damaged
Weight reading
is unstable
Over voltage
or affected by
moisture
Insufficient voltage
OR use of battery is
prolonged even after
the warning alarm OR
too much humidity in
surrounding
Charge the battery
for at least 10 hours;
Or clean the Mother
PCB for drying
Common Trouble Shooting