background image

8

9

09.07.2019

Parameter description

Parameter value

Product name

Multimeter 

Model

SBS-DMB-1000

Battery type

9V(6F22)/NEDA 1604

Rated power [W]

3

Over Voltage Protection

CATIII 1000

Measuring range of direct/

alternating current voltage

200mV~1000V/ 

2V~750V

Measuring range of direct/

alternating current amperage

2mA~20A/

2mA~20A

Measuring range of electrical 

resistance/capacitance

200Ω~20MΩ/ 

0.01~10μF-200µF

Protection rating IP

IP20

Maximum reading

1999

Working temperature / 

Relative working humidity

[°C, °F/%RH]

0 – 40/85 

Storage temperature/ Relative 

storage humidity [°C, °F/%RH] 

-10 – 50/85 

Dimensions [mm]

167x87x52 

Weight [kg]

0.281 

TECHNICAL DATA

The terms "device" or "product" are used in the warnings 

and instructions to refer to < Multimeter >. Do not use in 

very humid environments or in the direct vicinity of water 

tanks. Prevent the device from getting wet. Risk of electric 

shock! Do not cover the ventilation openings!

2.1. ELECTRICAL SAFETY

a) 

When measuring the voltage, make sure that the 

knob is set to appropriate range.

b) 

Exercise caution when measuring voltage above DC 

60V, AC 30V.

c)  If possible, avoid connecting the device to live 

circuits.

d) 

Before taking measurements of resistance, diode or 

continuity test, capacitance test or temperature test, 

make sure that the tested circuit is not live.

e) 

Before taking the measurements, make sure that the 

correct function and measuring range have been 

selected.

f) 

Take special care in the event of a break in the circuit 

when using the device in a system with an electric 

current transformer connected to the terminals.

g) 

Before every use, make sure that the test leads and 

probes are in good condition, e.g. the insulation is 

undamaged.

h) 

Before disassembling the battery cover, disconnect 

the test leads and probes from the device and set the 

rotary switch to the "OFF" position.

i) 

When measuring, make sure that you are holding 

the insulated parts of the test leads. 

j) 

Please observe general electrotechnical principles 

and guidelines when taking measurements.

k) 

A blown fuse must be replaced with a new one of the 

same types and specification.

l) 

Replace damaged test leads only with the same 

model or with the same electrical parameters.

m)  To avoid electric shock and damage to the 

instruments, do not exceed the limits of the input 

signals.

n)  Never change the position of the range switch 

during the measurement.

2.2. SAFETY IN THE WORKPLACE

a)  Do not use the device in a potentially explosive 

environment, for example in the presence of 

flammable liquids, gases or dust

b)  If you discover damage or irregular operation, 

immediately  switch  the  device  off  and  report  it  to 

a supervisor without delay.

c) 

If there are any doubts as to the correct operation 

of the device, contact the manufacturer's support 

service.

d) 

Only the manufacturer's service point may repair the 

device. Do not attempt any repairs independently!

e) 

In  case  of  fire,  use  a  powder  or  carbon  dioxide 

(CO2) fire extinguisher (one intended for use on live 

electrical devices) to put it out.

U S E R   M A N U A L

1. 

LCD display.

2. 

HOLD button/ Lock/unlock the displayed value. 

3. 

Turns the screen backlight on / off. The backlight will 

automatically turn off after 6 seconds. If the battery 

is running low, the backlight will dim.

4. 

LED informing about the continuity of the circuit

5. 

Input socket: hFE

6. 

Knob: switching off the device/selecting the function 

and measuring range. 

7. 

Input jack:

•  V /CAP, Ω

 

• 20A

• mA

• COM 

f) 

Regularly inspect the condition of the safety labels. If 

the labels are illegible, they must be replaced. 

g)  Please keep this manual available for future 

reference. If this device is passed on to a third party, 

the manual must be passed on with it.

h) 

Keep packaging elements and small assembly parts 

in a place not available to children.

i)  If this device is used together with another 

equipment, the remaining instructions for use shall 

also be followed.

2.3. PERSONAL SAFETY

a) 

Do not use the device when tired, ill or under the 

influence of alcohol, narcotics or medication which 

can  significantly  impair  the  ability  to  operate  the 

device.

b) 

The device is not designed to be handled by persons 

(including children) with limited mental and sensory 

functions or persons lacking relevant experience 

and/or knowledge unless they are supervised by 

a person responsible for their safety or they have 

received instruction on how to operate the device.

c) 

The device is not a toy. Children must be supervised 

to ensure that they do not play with the device.

2.4. SAFE DEVICE USE

a) 

When not in use, store in a safe place, away from 

children and people not familiar with the device who 

have not read the user manual. The device may pose 

a hazard in the hands of inexperienced users.

b)  Keep the device in perfect technical condition. 

Before each use check for general damage and 

especially check for cracked parts or elements and 

for any other conditions which may impact the safe 

operation of the device. If damage is discovered, 

hand over the device for repair before use. 

c) 

Keep the device out of the reach of children.

d) 

Device repair or maintenance should be carried out 

by qualified persons, only using original spare parts. 

This will ensure safe use.

e) 

To ensure the operational integrity of the device, do 

not remove factory-fitted guards and do not loosen 

any screws.

f) 

Do not leave this appliance unattended while it is in 

use.

g) 

Clean the device regularly to prevent stubborn grime 

from accumulating.

h) 

Do not cover the air intake and outlet.

i) 

The device is not a toy. Cleaning and maintenance 

may not be carried out by children without 

supervision by an adult person.

j) 

It is forbidden to interfere with the structure of 

the device in order to change its parameters or 

construction.

k) 

Keep the device away from sources of fire and heat.

Recording  of  accuracy:  ±  %  of  reading  +  number 

of last digits (at temperature: 18-28°C and humidity 

≤ 75% RH).

3.2. PREPARING FOR USE 

The temperature of environment must not be higher 

than 40°C and the relative humidity should be less than 

80%. The power cord connected to the appliance must be 

correspond to the technical details on the product label. 

Please note: The limit values for overload protection must 

not be exceeded.

Detailed (electrical) measurement parameters: 

The product satisfies the relevant safety 

standards.

Read instructions before use.

Recyclingprodukt.

Nur zur Verwendung in geschlossenen Räumen.

WARNING! or CAUTION! or REMEMBER! 

Applicable to the given situation (general 

warning sign).

1. GENERAL DESCRIPTION

The user manual is designed to assist in the safe and 

trouble-free use of the device. The product is designed 

and manufactured in accordance with strict technical 

guidelines, using state-of-the-art technologies and 

components. Additionally, it is produced in compliance 

with the most stringent quality standards.

DO NOT USE THE DEVICE UNLESS YOU HAVE 

THOROUGHLY READ AND UNDERSTOOD THIS 

USER MANUAL.

To increase the product life of the device and to ensure 

trouble-free operation, use it in accordance with this user 

manual and regularly perform maintenance tasks. The 

technical  data  and  specifications  in  this  user  manual  are 

up to date. The manufacturer reserves the right to make 

changes associated with quality improvement.

LEGEND

PLEASE NOTE!

 Drawings in this manual are for 

illustration purposes only and in some details, it may 

differ from the actual product.

The original operation manual is in German. Other 

language versions are translations from German.

2. USAGE SAFETY

ATTENTION! 

Read all safety warnings and all 

instructions. Failure to follow the warnings and 

instructions may result in serious injury or even death.

3. USE GUIDELINES

The device measures the electrical values and the 

temperatures of selected devices and electrical circuits. 

The user is liable for any damage resulting from 

unintended use of the device.

ATTENTION!

 Despite the safe design of the device 

and its protective features, and despite the use of 

additional elements protecting the operator, there is 

still a slight risk of accident or injury when using the 

device. Stay alert and use common sense when using 

the device.

3.1. DEVICE DESCRIPTION

ATTENTION! 

This product‘s view can be found on the 

last pages of the operating instructions (pp. 36).

• 

DC voltage

Range 

Accuracy

Resolution

200mV

0,5% +8

0.1mV

2V

1mV

20V

10mV

200V

100mV

1000V

1,5% +8

1V

Overload protection: 250V for 200mV, effective DC 100V or 

AC 600V for other ranges.

Impedance: 10MΩ.

• 

AC voltage (RMS)

Range

Accuracy

Resolution

Frequency

2V

1,5% +10 

1mV

40~400Hz

20V

10mV

200V

100mV

750V

2,5% +10

1V

Average detection: calibrated to RMS (average square) of 

a sine wave.

EN

EN

Summary of Contents for SBS-DMB-1000

Page 1: ...NGSANLEITUNG MULTIMETER USER MANUAL MULTIMETER INSTRUKCJA OBS UGI MULTIMETR N VOD K POU IT MULTIMETR MANUEL D UTILISATION MULTIM TRE ISTRUZIONI PER L USO MULTIMETRO MANUAL DE INSTRUCCIONES MULT METRO...

Page 2: ...Sie die Messungen durchf hren f Bei Verwendung des Ger tes mit angeschlossenem Stromwandler ist bei einem Stromausfall besondere Vorsicht geboten g Vor jedem Gebrauch sollte sichergestellt werden dass...

Page 3: ...ationsaufkleber Falls die Aufkleber unleserlich sind sollten diese erneuert werden g Bewahren Sie die Gebrauchsanleitung f r den weiteren Gebrauch auf Sollte das Ger t an Dritte weitergegeben werden m...

Page 4: ...glich eine h here Spannung anzuzeigen aber es kann die internen Schaltkreise des Ger tes besch digen oder einen elektrischen Schlag verursachen Dass der Maximalstrom der mA Buchse 200 mA und der Maxim...

Page 5: ...levant experience and or knowledge unless they are supervised by a person responsible for their safety or they have received instruction on how to operate the device c The device is not a toy Children...

Page 6: ...ransistor is NPN or PNP locate the emitter base and collector leads 3 Insert the leads into the proper holes of the hFE socket on the front panel 4 Read the approximate hFE value 3 3 1 9 BATTERY TEST...

Page 7: ...cznie serwis producenta Nie wolno dokonywa napraw samodzielnie e W przypadku zapr szenia ognia lub po aru do gaszenia urz dzenia pod napi ciem nale y u ywa wy cznie ga nic proszkowych lub niegowych CO...

Page 8: ...ieraj ce substancji r cych b Po ka dym czyszczeniu wszystkie elementy nale y dobrze wysuszy zanim urz dzenie zostanie ponownie u yte c Urz dzenie nale y przechowywa w suchym i ch odnym miejscu chronio...

Page 9: ...rozsah m en f Bu te obzvl t opatrn dojde li k p eru en obvodu kdy za zen pou v te v syst mu s proudov m transform torem p ipojen m ke kle t m g P ed ka d m pou it m zkontrolujte zda jsou testovac kab...

Page 10: ...sv cen sni uje sv j jas 4 Dioda informuj c o spojitosti obvodu 5 Vstupn zd ka hFE 6 Regul tor vypnut p stroje volba funkce a rozsahu m en 7 Vstupn z suvka V CAP 20A mA COM CZ f Je t eba pravideln kont...

Page 11: ...n sb rn opot eben ch za zen poskytne m stn obecn nebo m stsk ad Le produit est conforme aux normes de s curit en vigueur Respectez les consignes du manuel Collecte s par e Description des param tres...

Page 12: ...s sensorielles ou mentales sont limit es enfants y compris ni par des personnes sans exp rience ou connaissances ad quates moins qu elles se trouvent sous la supervision et la protection d une personn...

Page 13: ...200 mA et que le courant maximal pour 10A est de 10A le d passement de ces limites d truira le fusible La plage de 10 A n tant pas prot g e le temps de mesure doit tre inf rieur 1 seconde pour viter t...

Page 14: ...i moderne e seguendo gli standard di qualit pi elevati PRIMA DELLA MESSA IN FUNZIONE NECESSARIO AVER LETTO E COMPRESO LE ISTRUZIONI D USO Per un funzionamento duraturo e affidabile del dispositivo ass...

Page 15: ...terminale di ingresso COM e il cavo rosso al terminale V CAP 2 Portare il commutatore rotante nella posizione 200uF 3 Collegare le sonde al componente in prova 4 Leggere il risultato sul display LCD A...

Page 16: ...s que est n sometidos a tensi n d Antes de medir la resistencia hacer las pruebas de diodos o continuidad la prueba de capacidad o la prueba de temperatura aseg rese de que el circuito analizado no es...

Page 17: ...tecci n frente a sobrecargas Par metros el ctricos detallados de las mediciones Registro de precisi n de la lectura la cantidad de las ltimas cifras a temperatura de 18 28 C y humedad relativa de 75 E...

Page 18: ...o provocar una descarga el ctrica que la corriente m xima de mA es de 200mA y que el m ximo para 10A es 10A excediendo estos l mites destruir el fusible Como el rango de 10 A no est protegido el tiemp...

Page 19: ...produit Mod le IT Importatore Nome del prodotto Modello ES Importador Nombre del producto Modelo 4 5 6 DE Batterietyp Produktionsjahr Ordnungsnummer EN Battery type Production year Serial No PL Typ b...

Page 20: ...38 39 09 07 2019 NOTES NOTIZEN NOTES NOTIZEN...

Page 21: ...r Verf gung stehenden M glichkeiten der R ckgabe oder Sammlung von Altger ten 1 RICHTLINIE 2002 96 EG DES EUROP ISCHEN PARLAMENTS UND DES RATES BER ELEKTRO UND ELEKTRONIK ALTGER TE 2 Gesetz ber das In...

Reviews: