STEINDORFF

®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 

11 

12 

13 

14 

15 

16 

17 

18 

19 

20 

List of Parts 

1.

 

Eyepiece 

2.

 

Binocular Head 

3.

 

Bertrand Lens 

4.

 

Compensator Socket 

5.

 

Clamp Screw 

6.

 

Stage Height Adjustment Screw 

7.

 

Coarse Focusing Knobs 

8.

 

Fine Focusing Knobs 

9.

 

Condenser Centering Screws 

10.

 

Condenser Focusing Knob 

11.

 

Brightness Control 

12.

 

Power Switch 

13.

 

Power Indicator 

14.

 

Light Collector 

15.

 

Graduated Marks of Polarizer 

16.

 

Iris Diaphragm Lever 

17.

 

Stage Centering Screws (Detachable) 

18.

 

Nosepiece 

19.

 

Graduated Marks on Analyzer 

20.

 

Analyzer Lever 

 

Summary of Contents for NYMC62B00

Page 1: ...STEINDORFF NYMC62B00 Polarizing Microscope ...

Page 2: ...tage Height Adjustment Screw 7 Coarse Focusing Knobs 8 Fine Focusing Knobs 9 Condenser Centering Screws 10 Condenser Focusing Knob 11 Brightness Control 12 Power Switch 13 Power Indicator 14 Light Collector 15 Graduated Marks of Polarizer 16 Iris Diaphragm Lever 17 Stage Centering Screws Detachable 18 Nosepiece 19 Graduated Marks on Analyzer 20 Analyzer Lever ...

Page 3: ...ications 1 Observation Tube Binocular Head 2 Objectives stress less achromatic objectives Magnifying Power Objectives Numerical Aperture N A Thickness of Cover Glass 4x 0 10 10x 0 25 20x 0 40 40x 0 65 0 17 60x optional 0 85 0 17 3 Eyepieces Type Magnifying Power Standard Eyepiece Pair 10x Eyepiece with Crosshairs 5x Eyepiece with Graticule 10x 4 Final magnifying powers of objectives and eyepieces ...

Page 4: ...he lever for pulling the analyzer out from the light path Open the Iris Diaphragm Make sure that the field Iris Diaphragm coincides with the field of view 2 Secure the specimen properly with the clips on the Rotary Stage 3 Adjust the center of the stage using the stage centering screw Focus the specimen sharply Find a marked feature in the field of view and make it to situate at the center of the ...

Page 5: ...d for high power examination Insert Bertrand lens into the light path when using orthogonal polarizing light The swinging upper lenses of the condenser are arranged so that they may be moved into the optical axis of the microscope for examining the conical characteristic of the specimen 7 When an indistinct image of the filament of the bulb reveal in the field of view add a ground glass properly W...

Page 6: ...ismantle any part of the instrument If there is any dirt on the surfaces of the lens wipe it off gently with some absorbent cotton moistened with xylene Dust on the lens surfaces can be blown off by using an air blower 2 Oil the mechanical moving parts of the instrument with some watch or clock lubricant 3 Avoid contacting high temperature 4 Objectives and eyepieces should replace back to their co...