HG ROOF
Maintenance and Repair
24
X4 Testing the motor
1. There are usually no problems with the motor (the PCB more often needs to be replaced) but there is a
simple test for the motor. Place the chain on the sprocket and you can easily turn the motor.
2. Short together the blue/red to the yellow/black and there is strong resistance when turning the motor.
1
2