– 16 –
GB
1. About this document
Please read carefully and keep in a safe place.
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
...
Reference to other information in the
document.
2. General safety precautions
!
Disconnect the power supply before
attempting any work on the unit.
During installation, the electric power cable being
connected must not be live. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing the sensor-switched light involves work
on the mains supply voltage. This work must
therefore be carried out professionally in accord-
ance with national wiring regulations and elec-
trical operating conditions. (e.g.
DE
-VDE 0100,
AT
-ÖVE / ÖNORM E8001-1,
CH
-SEV 1000)
• Only use genuine replacement parts.
• Repairs may only be made by specialist work-
shops.
• The light source of this light cannot be replaced.
If the light source needs to be replaced (e.g. at
the end of its service life), the complete light must
be replaced.
3. RS PRO Connect R10 /
RS PRO Connect R20 /
RS PRO Connect R30
Proper use
– Sensor-switched indoor light with active motion
detector for installing indoors.
– Can be retrofitted with emergency light
The integrated HF sensor emits high-frequency
electromagnetic waves (5.8 GHz) and receives their
echo. The change in echo caused by the slightest
movement within the light's detection zone is
detected by the sensor.
A microprocessor then issues the switch command
"switch light ON". Detection is possible through
doors, panes of glass or thin walls.
Note:
The high-frequency power of the HF sensor is
approx. 1 mW – that is 1000 times less than the
transmission power of a mobile phone or micro-
wave oven.
Package contents, round
(Fig. 3.1)
Sensor-switched light
3 spacers
2 slot-in shrouds
Product dimensions, round
(Fig. 3.2)
Product components, round
(Fig. 3.3)
A
Light enclosure
B
Wall mount
C
Connecting terminal
D
Slot-in shrouds
E
Catches for slot-in shrouds
Package contents, square
(Fig. 3.4)
Sensor-switched light
3 spacers
2 slot-in shrouds
Product dimensions, square
(Fig. 3.5)
Product components, square
(Fig. 3.6)
A
Light enclosure
B
Wall mount
C
Connecting terminal
D
Slot-in shrouds
E
Catches for slot-in shrouds
4. Electrical connection
• Switch OFF power supply
(Fig. 4.1)
Connecting the mains power supply lead
(Fig. 4.1)
The supply lead is a three-core cable:
L
= phase conductor (usually black, brown or
grey)
N
= neutral conductor (usually blue)
PE
= protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from the
power supply again. Connect phase
(L)
and neutral
conductor
(N)
to the terminal.