- 18 -
- 19 -
Button for light functions
f
Sensor mode
The Sensor Switch basically operates in sensor
mode. The light is switched ON for the preset
time in response to movement within the
detection zone.
Permanent light mode
Button 1 x ON
The connected light is set to permanent light
for 4 hours (red LED illuminates). After this
period, the Sensor Switch immediately returns
to sensor mode (red LED OFF).
Permanent light can be interrupted before
this time elapses by pressing the button
(red LED OFF).
Permanent light OFF mode
Press button for 3 sec.
The connected light is switched OFF
(red LED flashes).
By briefly pressing the button again, the Sensor
Switch returns immediately to sensor mode
(red LED OFF).
1 x 3 sec.
OFF
1 x short
max. 4 hours
Sensor
5 sec. - 30 min.
Functions
(only for HF 360 UP)
Reach setting (sensitivity)
k
The term reach denotes the approximately
circular diameter that results as the detection
zone. Adjusting screw left stop position means:
minimum reach (approx. 1 m / factory setting).
Adjusting screw right stop position means:
maximum reach (approx. 8 m).
1 - 8 m
30
2
LUX
Twilight setting (Response threshold)
i
The desired sensor response threshold can be
adjusted continuously from approx. 2 lux to
2000 lux.
Adjusting screw right stop position means:
Daylight operation approx. 2000 lux (factory
setting). Adjusting screw left stop position
means: Night-time operation approx. 2 lux.
When adjusting the detection zone and for
the performance test in daylight, the adjusting
screw must be set to the right stop position.
2 - 2000 lux
Time setting (Switch-off delay)
j
The desired duration of illumination of the con-
nected light can be continuously adjusted from
approx. 5 sec. to max. 30 min.
Adjusting screw left stop position means:
shortest time approx. 5 sec. (factory setting)
Adjusting screw right stop position means:
longest time approx. 30 min.
The timer is restarted by any motion detected
before this time elapses. The shortest time set-
ting is recommended when adjusting the de-
tection zone and performing a functional test.
Note:
After every off switching, further motion
detection is interrupted for approx. 2 seconds.
Only after this time elapses is it possible for the
Sensor Switch to switch light again.
30
2
LUX
5 sek. - 30 min.