- 20 -
- 21 -
Operation/Maintenance
The Sensor Switch is suitable for au-
tomatic switching of light. The unit is
not suitable for special burglary alarm
systems, since it lacks the sabotage
protection prescribed for this purpose.
The surface should be cleaned if dirty
with a damp cloth (without cleaners).
Declaration of conformity
STEINEL Vertrieb GmbH hereby
declares that the HF 360 AP radio
equipment type conforms to Directive
2014/53/EU. The full wording of
the EU Declaration of Conformity is
available for downloading from the
following Internet address:
http://www.steinel.de
Manufacturer's warranty
This STEINEL product has been
manufactured with great care, and its
operation and safety have been tested
in conformity with the current regula-
tions. Production is also submitted
to final random-sample testing.
STEINEL guarantees that it is in
perfect condition and proper work-
ing order.
The warranty period is 36 months,
starting on the date of sale to the user.
We undertake to remedy faults caused
by material or manufacturing defects.
This warranty undertaking shall be
performed by the repair or replace-
ment of the defective parts, at our
own discretion.
This warranty shall not cover dam-
age to wearing parts or damage and
faults caused by incorrect operation
or maintenance. Further consequential
damage to external items is excluded.
Claims under warranty shall only be
accepted if the product is sent fully
assembled and well packed complete
with sales slip or invoice (date of pur-
chase and dealer’s stamp) to the ap-
propriate Service Centre or handed in
to the dealer within the first 6 months.
Repair Service:
Please ask your nearest service centre
how to proceed for repairing faults not
covered by the warranty or occurring
after the warranty expires.
MANUFACTURER'S
1
3
5
Y E A R
G B
WARRANTY
MANUFACTURER'S
Y E A R
WARRANTY
MANUFACTURER'S
Y E A R
WARRANTY
Troubleshooting
Malfunction
Cause
Remedy
Sensor Switch
without power
n
Fuse blown,
not switched ON
n
Short circuit
n
Replace fuse; switch
ON mains switch;
check wiring with
voltage tester
n
Check connections
Sensor Switch
does not switch ON
n
Twilight setting in
night-time mode dur-
ing daytime operation
n
Additional two-way
switch OFF
n
Fuse blown
n
Readjust
n
Switch power on
n
New fuse, check con-
nection if required
Sensor Switch
does not switch OFF
n
Continued movement
within the detection
zone
n
Switched ON light is
within detection zone
of IR 180 UP and
switches ON again as
a result of tempera-
ture change
n
Permanent light op-
eration switched ON
(red LED illuminates)
n
Other Sensor Switch
is parallel-connected
and still active
n
Check detection zone
n
Check detection zone
n
Switch off permanent
light operation
n
Await time setting
of the other Sensor
Switch
Sensor Switch
keeps switching ON/OFF
n
Switched ON light
is within IR 180 UP
detection zone
n
Animals moving in
IR 180 UP detection
zone
n
Curtains, flowers,
etc. move within the
detection zone of the
HF 360 UP and cause
switching again by
motion
n
Check detection zone
n
Check detection zone
n
Check detection zone
Sensor Switch
does not switch ON
n
Light bulb burnt out
n
Replace light bulb