background image

 

 

6918600000

 

 

 

22

 

WIRING DIAGRAM 
 

 

 
CONNECTIONS 

7 WAYS CONNECTOR                                                                           FRONT VIEW CONNECTOR 
 

 

 
FRONT CONNECTIONS 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

7 WAYS 
CONNECTOR 

PIN 

DESCRIPTION 

TORCH SWITCH 

TORCH TRIGGER 

TORCH SWITCH

 

MIN POTENTIOMETER 

MAX POTENTIOMETER 

 
REMOTE CONTROL 

REG POTENTIOMETER 

TYPE 

CONNECTION 

PIN  DESCRIPTION 

EARTH CLAMP 

POSITIVE 

GAS 

GAS 

TORCH CONN. 

YES 

TIG 

TIG TORCH 

NEGATIVE

 

TYPE 

CONNECTION 

PIN  DESCRIPTION 

ELECTRODE 

POSITIVE 

GAS 

NO 

REMOTE CONN. 

REMOTE CONTROL 
CONNECTOR. 

MMA 

EARTH CLAMP 

NEGATIVE

 

1

2

3

4

5

6

7

 

Summary of Contents for TIG dp 181H

Page 1: ...000 1 MANUALE DI ISTRUZIONE PER SALDATRICE INSTRUCTION MANUAL FOR WELDING MACHINE BETRIEBSANLEITUNG F R SCHWEI ER TE TIG TIG TIG TIG dp dp dp dp 181H 181H 181H 181H Info www stelgroup com tel 39 0444...

Page 2: ...onized standard in force within the EEA has been used in the design EN 60974 1 Arc welding equipment Part 1 Welding power sources EN 60974 10 Arc welding equipment Part 10 Electromagnetic compatibilit...

Page 3: ...E LA VOSTRA SALUTE Tenere il capo fuori dalla portata dei fumi Provvedere per una ventilazione adeguata dell area di lavoro Se la ventilazione non sufficiente usare un aspiratore che aspiri dal basso...

Page 4: ...denza dei cavi di saldatura I comandi sul pannello frontale consentono una facile programmazione delle sequenze di saldatura in funzione delle esigenze operative La tecnologia inverter usata ha permes...

Page 5: ...enti nel paese di utilizzo L impianto di rete deve essere di tipo industriale Predisporre una apposita spina che preveda l alloggiamento dei conduttori del cavo di alimentazione Per i cavi pi lunghi m...

Page 6: ...TTRODO In Modalit stick Tenere premuto il pulsante SELECT MODE sul pannello frontale della macchina per circa 3 secondi rilasciare poi il pulsante ed eseguire una pressione del pulsante successiva il...

Page 7: ...niche che anticorrosive GAS Il gas di protezione normalmente usato l argon puro con una quantit variabile a seconda della corrente impiegata 4 6 I min SALDATURA TIG DEL RAME Per le propriet gi descrit...

Page 8: ...lettriche assieme ai rifiuti normali In ottemperanza alla Direttiva Europea 2002 96 CE sui rifiuti da apparecchiature elettriche ed elettroniche e relativa attuazione nell ambito della legislazione na...

Page 9: ...ersons PREVENTION OF ELECTRIC SHOCKS Take the following precautions when working with a welding machine keep yourself and your clothes clean do not be in contact with damp or wet parts when working wi...

Page 10: ...sumption excellent dynamic response very high power factor and yields better welding characteristics viewing of the data and of the set functions on the display The electronic components are enclosed...

Page 11: ...ndustrial type Provide a special socket which can receive leads For longer connecting cables increase the lead section as required Upstream the mains socket must have a suitable switch provided with d...

Page 12: ...r about 3 seconds release and press again the same button The Sub Menu LED 22 will blink and the display will show H S Regulate the encoder 13 to change the value of the Hot Start from 0 to Max 50 of...

Page 13: ...th mechanical and anti corrosive GAS The shielding gas normally used is pure argon with a gas flow rate that varies according to the current used and joint set up 4 6 I min TIG WELDING ON COPPER Due t...

Page 14: ...pose of electrical equipment together with normal waste In observance of European Directive 2002 96 EC on Waste Electrical and Electronic Equipment and its implementation in accordance with national l...

Page 15: ...eine entflammbaren Dinge mit sich wie Feuerzeuge oder Streichh lzer Der Lichtbogen kann Br nde verursachen Halten Sie die Spitze der Elektrode von Ihrem K rper sowie von Personen in Ihrer N he fern VO...

Page 16: ...ingem Gewicht und kompakten Abmessungen geringerer Energieverbrauch ausgezeichnetes dynamisches Ansprechen sehr hoher Leistungsfaktor und Wirkungsgrad bessere Schwei eigenschaften Anzeigen der Daten u...

Page 17: ...pannung 230V Mindestspannung 184V H chstspannung 276V Tig dp 181H Sicherung 16A ANSCHLUSS Bevor Sie den elektrischen Anschluss zwischen dem Schwei ger t und dem Leitungsschalter herstellen stellen Sie...

Page 18: ...unktionen 9 Led zur Anzeige des Base Current 2 10 90 10 Led zur Anzeige der GASNACHSTR MUNG 0 1 10 Sek 11 Led zum Einschalten der Pulsfunktion 12 Led zur Anzeige der eingeschalteten Pulsfunktion 13 En...

Page 19: ...m Encoder 13 die 2T oder 4T Funktion w hlen DUTY REGULIERUNG UND PULSFREQUENZ 1 Die Pulsfunktion durch Bet tigen des Druckknopfs 11 w hlen die Led 12 aufleuchtet 2 Den Druckknopf 11 mehrmals bet tigen...

Page 20: ...len beschriebene die Vorbereitung erfolgt ebenfalls wie bereits beschrieben Um die potentielle Oxydation der Schwei stelle zu vermeiden werden Zusatzwerkstoffe mit Phosphor Silizium und desoxydierende...

Page 21: ...lter Board Isolator Side Label Stel Side Label HF generator Board Rear Panel Power Input Cable Power Switch 61320700 64421000 63266000 64436000 66046700 6608120L 61133100 6205770T 61139200 61141500 66...

Page 22: ...IGGER 7 TORCH SWITCH 2 MIN POTENTIOMETER 4 MAX POTENTIOMETER REMOTE CONTROL 5 REG POTENTIOMETER TYPE CONNECTION PIN DESCRIPTION EARTH CLAMP A POSITIVE GAS B GAS TORCH CONN C YES TIG TIG TORCH D NEGATI...

Page 23: ...6918600000 23 WELDING TABLE STEEL...

Page 24: ...6918600000 24 Info www stelgroup com tel 39 0444 639525...

Reviews: