3
9
CONNECTING THE ELECTRICAL WIRES
1 -
Using the supplied connection caps,*
connect the Allia thermostat wires
to those of the heating system and
power supply wires according to the
corresponding connection diagram.
2 -
Tighten the caps on the wires to make
sure the connection is secure.
3 -
Then, place all the wires in the
electrical box.
For baseboards,
convectors and
fan heaters
3 CONNETORS
UNIVERSAL
CONNECTION
For baseboards,
convectors and
fan heaters
3 CONNETORS
ALTERNATIVE
CONNECTION
For baseboards
and convectors
only
2 CONNECTORS
CONNECTION
L1
Black
L2/N
Red
LD
Yellow
WARNING
: Improperly connected electrical wires are a fire hazard.
The direction of the connection
is important since the
thermostat wires are polar.
*If the power supply wires are made of aluminium, use CO/ALR connection caps instead (not supplied).
LOAD
POWER
LOAD
LOAD
POWER
LOAD
POWER
LOAD
LOAD
POWER
LOAD
POWER
LOAD
LOAD
POWER