INSSEFECMI0513

specifications

elecTRic fuRNace

Type

volTs

kW

amp

hp

leNgTh (iN.)

WidTh (iN.)

depTh (iN.)

lB

kg

sefecm1021B

240/208

10/7.5

44/38

1/2 ECM

36 9/16

20 1/8

21 3/16

100

45

sefecm1521B

240/208

15/11.2

65/56

1/2 ECM

36 9/16

20 1/8

21 3/16

100

45

sefecm1821B

240/208

18/13.5

78/67

1/2 ECM

36 9/16

20 1/8

21 3/16

100

45

sefecm2021B

240/208

20/15

86/75

1/2 ECM

36 9/16

20 1/8

21 3/16

100

45

sefecm2321B

240/208

23/17.2

98/85

1/2 ECM

36 9/16

20 1/8

21 3/16

100

45

sefecm2721B

240/208

27/20.2

118/102

1 ECM

36 9/16

20 1/8

21 3/16

105

48

sefecm3021B

240/208

30/22.5

130/113

1 ECM

36 9/16

20 1/8

21 3/16

105

48

N.B. cut off power supply at circuit breaker/fuse before proceeding to the installation.

Please note that each furnace is factory inspected before shipping in order to ensure that every component is operating efficiently.
The “SEFECM’’ series electric furnace is available in several models of various heating capacity (from 10 to 30 kW). All these models adapt easily 

to many applications and are suitable for 

horizontal, upflow 

and

 downflow

 operations (see the figures below). When installed in vertical 

downflow position, use only ‘‘L’’ or ‘‘T’’ shaped plenum without openings or registers directly below the unit.

installation

LoCATion

You must install the furnace on a dry and solid base, in an area free of flammable liquids or vapors and combustible materials. You must 

indicate to the furnace user the location of the switches and disconnects. He must be able to quickly identify them in case of an emergency. 

Moreover, the furnace should be located as centrally as possible in the area to heat in order to optimize air dissipation in all the rooms.

CLeArAnCe

This furnace is approved for ‘‘zero inch’’ clearance. Meaning that you can install it directly against a wall. Ducts for models of 23 kW and 

less can also be installed with a zero inch clearance (0 inch). However, ducts for models of 27 kW and more must have a 1-inch clearance 

for the first 36 inches of duct. From 37 inches, this clearance can be reduced to 0 inch. Please refer to the codes effective in your region if 

you have any questions concerning clearances.
Since it is necessary to open the door in the front to perform the furnace maintenance inspection, you must leave at least a 24-inch 

clearance in front of this door.

DISCHARGE

DISCHARGE

DISCHARGE

UPFLOW POSITION

HORIZONTAL POSITION

DOWNFLOW POSITION

AIR RETURN

AIR RETURN

AIR RETURN

SEE EFFECTIVE 

CODES FOR THE 

FLOOR ADAPTOR

COMBUSTIBLE 

FLOOR

DISCHARGE

DISCHARGE

DISCHARGE

UPFLOW POSITION

HORIZONTAL POSITION

DOWNFLOW POSITION

AIR RETURN

AIR RETURN

AIR RETURN

SEE EFFECTIVE 

CODES FOR THE 

FLOOR ADAPTOR

COMBUSTIBLE 

FLOOR

Summary of Contents for SEFECM Series

Page 1: ...r further information or to consult this guide online please visit our website at www stelpro com This unit complies with CSA and UL standards This unit is approved according to the Canadian and Ameri...

Page 2: ...ouch hot surfaces Let the unit cool down for a few minutes before handling it it stays warm for some time after shut down Never block air vents This obstruction could lead to overheating which could r...

Page 3: ...tion Location You must install the furnace on a dry and solid base in an area free of flammable liquids or vapors and combustible materials You must indicate to the furnace user the location of the sw...

Page 4: ...e between 40 C 104 F and 70 C 158 F Optional accessories The furnace is equipped with all the devices required for the addition of an air conditioner or a heat pump except the heat cool thermostat The...

Page 5: ...rnace at 208 VAC you must change a connection on the 24 V terminal board of the transformer see the illustration below Refer to the local and national electrical codes to know which wire size fuses an...

Page 6: ...t or heat of the sun a lamp a fireplace or any other heat source close or in front of an air outlet close to concealed ducts or a chimney and in a location with poor air flow e g behind a door or with...

Page 7: ...EATING button provides the selection of the 5 kW continuous heating mode 8 5 kW CONTINUOUS HEATING pilot light indicates that the 5 kW continuous heating mode is activated This mode is pending if the...

Page 8: ...tivate the 100 capacity Continuous ventilation Two ventilation speeds can be selected on the furnace control panel Low speed continuous ventilation or High speed continuous ventilation If the pilot li...

Page 9: ...r conditioning A potentiometer allowing to adjust the airflow corresponds to each of these five modes The potentiometers are located in front of the furnace electrical panel The adjustment scales of t...

Page 10: ...at is set off This means that there is a risk of electric shock as long as the unit is energized Preventive maintenance Do not try to repair your furnace yourself Call a qualified technician However b...

Page 11: ...the unit capacity Faulty relay Control card autodiagnostic The control card of the furnace is equipped with three LED pilot lights that allow easy and quick diagnostic of its essential functions They...

Page 12: ...SEFECM2021 9 CIR 003 SEFECM2321 MAIN CONTROL CARD SEFECM2321 9 CIR 003 SEFECM2721 MAIN CONTROL CARD SEFECM2721 9 CIR 003 SEFECM3021 MAIN CONTROL CARD SEFECM3021 10 CIR 005 SEFECM1021 CONTROL CIRCUIT B...

Page 13: ...y for property or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shu...

Page 14: ......

Reviews: