background image

INSSPDH0414

4

n.B. the unit should be cleaned at least once a year. all other 

servicing  is  to  be  done  by  qualified  service  personnel.  this 

unit must be cleaned regularly in order for the warranty to be 

valid. make sure the power has been turned off at the circuit 

breaker panel and that the heating element has cooled before 

cleaning  the  unit  or  before  removing  grill  for  cleaning  and 

lubrication.

use a soft rag for dusting. When cleaning, use only a damp rag and non-abrasive 

dish soap. Do not use abrasive or chemical cleaners because they may damage 

the finishing. If the unit is used in a very dusty location, use a vacuum brush to 

remove dust and other foreign objects from the grills. If needed, vacuum out the 

dust inside the unit. Note that cigarette smoke could yellow the discharge grill 

and that the best way to prevent it is to clean the unit on a regular basis.

Don’t forget to replace front grille (with the screws that were removed) if it was 

removed for cleaning.
Restore the power when cleaning or lubrication work is complete.

do not use cleaning products identified with these symbols:  

n.B. note that there is electrical current linked to the unit 

even if the thermostat is set off. this means that there is a 

risk of electric shock as long as the unit is energized.

N.B.: If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the 

“Limited warranty” section to obtain the phone numbers).

pRoBLem

deFectiVe paRt oR paRt to checK

The unit does not work

• Open circuit breaker or fuse

• The thermal protection has been activated

• Faulty connections

The unit becomes extremely hot

•  The unit cycles under control of the thermal protection or this latter is defective

• Blocked air vents

The unit cycles under control of the thermal protection (overheat 

indicator)

• Blocked air vents

The breaker trip when the heater is turned on

• Faulty connections

• Voltage lower than that written on the nameplate

maINteNaNce

troubleSHootING

eleCtRICal wIRINg

•  This unit must be connected to a 240 volt power source.
•   To ground the heater, you must connect the green wire coming from the circuit breaker panel to the green screw located inside the junction box of the heater. 

OpeRatION

WaRning : the unit must be properly installed before being used.

eleCtRICal dIagRam

ALIMENTATION

L2 / N

L1

GND

A

ÉLÉMENT

E

POWER SUPPLY

L2 / N

L1

GND

A

HEATING

E

ALIMENTATION

GND

L3

L1

A

ÉLÉMENT

E

L2

A

POWER SUPPLY

GND

L3

L1

A

HEATING

E

L2

A

MISE À LA TERRE

PROTECTION THERMIQUE

CONNEXION EXTÉRIEURE

G14

ÉLÉMENT

GROUND

THERMAL PROTECTION

OUTSIDE CONNECTION

G14

ELEMENT

oPeration, maintenance & troUblesHooting