INSSPDH0414
4
n.B. the unit should be cleaned at least once a year. all other
servicing is to be done by qualified service personnel. this
unit must be cleaned regularly in order for the warranty to be
valid. make sure the power has been turned off at the circuit
breaker panel and that the heating element has cooled before
cleaning the unit or before removing grill for cleaning and
lubrication.
use a soft rag for dusting. When cleaning, use only a damp rag and non-abrasive
dish soap. Do not use abrasive or chemical cleaners because they may damage
the finishing. If the unit is used in a very dusty location, use a vacuum brush to
remove dust and other foreign objects from the grills. If needed, vacuum out the
dust inside the unit. Note that cigarette smoke could yellow the discharge grill
and that the best way to prevent it is to clean the unit on a regular basis.
Don’t forget to replace front grille (with the screws that were removed) if it was
removed for cleaning.
Restore the power when cleaning or lubrication work is complete.
do not use cleaning products identified with these symbols:
n.B. note that there is electrical current linked to the unit
even if the thermostat is set off. this means that there is a
risk of electric shock as long as the unit is energized.
N.B.: If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the
“Limited warranty” section to obtain the phone numbers).
pRoBLem
deFectiVe paRt oR paRt to checK
The unit does not work
• Open circuit breaker or fuse
• The thermal protection has been activated
• Faulty connections
The unit becomes extremely hot
• The unit cycles under control of the thermal protection or this latter is defective
• Blocked air vents
The unit cycles under control of the thermal protection (overheat
indicator)
• Blocked air vents
The breaker trip when the heater is turned on
• Faulty connections
• Voltage lower than that written on the nameplate
maINteNaNce
troubleSHootING
eleCtRICal wIRINg
• This unit must be connected to a 240 volt power source.
• To ground the heater, you must connect the green wire coming from the circuit breaker panel to the green screw located inside the junction box of the heater.
OpeRatION
WaRning : the unit must be properly installed before being used.
eleCtRICal dIagRam
ALIMENTATION
L2 / N
L1
GND
A
ÉLÉMENT
E
POWER SUPPLY
L2 / N
L1
GND
A
HEATING
E
ALIMENTATION
GND
L3
L1
A
ÉLÉMENT
E
L2
A
POWER SUPPLY
GND
L3
L1
A
HEATING
E
L2
A
MISE À LA TERRE
PROTECTION THERMIQUE
CONNEXION EXTÉRIEURE
G14
ÉLÉMENT
GROUND
THERMAL PROTECTION
OUTSIDE CONNECTION
G14
ELEMENT
oPeration, maintenance & troUblesHooting