INSSTE403NP1010
Limited warranty
This unit has a
3-year warranty. If at any
time during this period the unit becomes
defective, it must be returned to its place
of purchase with the invoice copy, or
simply contact our customer service de-
partment (with an invoice copy in hand).
In order for the warranty to be valid, the
unit must have been installed and used
according to instructions. If the installer
or the user modifies the unit, he will be
held responsible for any damage result-
ing from this modification. The warranty
is limited to the factory repair or the
replacement of the unit, and does not
cover the cost of disconnection, trans-
port, and installation.
Customer service
Stelpro Design inc.
1041, Parent Street
St-Bruno (Quebec)
Canada J3V 6L7
E-mail: contact@stelpro.com
Web site: www.stelpro.com
5. Technical specifications
Supply voltage:
120 to 347 VAC, 50/60 Hz
Minimum electrical current with a resistive load:
1.2 A
400 W @ 347 VAC
Maximum electrical current with a resistive load:
16.7 A
5750 W @ 347 VAC
Temperature display range:
0°C to 40°C (32°F to 99.5°F)
Temperature display resolution:
0.5°C (0.5°F)
Temperature set point range:
3°C to 30°C (37°F to 86°F)
Temperature set point increments:
0.5°C (1°F)
Storage temperature:
-20°C to 50°C (-4°F to 120°F)
Certification:
cCSAus