background image

INSSTE403NP1010

Ambient temperature

The figures displayed above the 

 icon indi-

cate  the  ambient  temperature,  ±  0.5  degree. 
Temperature can be displayed in degrees Cel-
sius or Fahrenheit (see “Display in degrees Cel-
sius/ Fahrenheit”).

Temperature set point

The figures displayed above the   icon indicate 
the temperature set point. It can be displayed 
in degrees Celsius or Fahrenheit (see “Display 
in degrees Celsius/Fahrenheit”).
To adjust the set point, just 
press  down  the  right  but-
ton  to  increase  the  value, 
or  the  left  button  to  de-
crease  it.  Set  points  can 
be adjusted by increments 
of 0.5°C or 1°F. To quickly 
scroll through the set point 
values,  press  and  hold  down  the  button.  The 
minimum set point is 3°C (37°F), and the maxi-
mum set point is 30°C (86°F).

In Day mode, you can turn off the thermostat 
by  lowering  the  set  point  below  3°C.  The  set 
point value displayed will be --.-, and heating 
system start up will be impossible.

Day mode and Night mode  
The  thermostat  includes  a  Day  mode  and  a 
Night mode, both of them having their own in-
dependently adjustable and recorded set point. 
When  switching  from  one  mode  to  the  other, 
the system will automatically use the tempera-

ture set point corresponding to the Day/Night 
mode selected. The standard factory set point 
adjustment is 21°C for the Day mode, and 18°C 
for the Night mode.
The current Day/Night mode selection is indi-
cated on the display by the 
Sun  or  Moon  icon.  In  order 
to manually switch from one 
mode  to  the  other,  simulta-
neously press down the two 
buttons  and  release  them 
immediately.

Night mode timer
The Night mode features a timer that automati-
cally returns to the Day mode after a selectable 
time  period.  This  timer  allows  the  temporary 
use  of  a  temperature  set  point.  The  standard 
factory  adjustment  of  the  timer  is  8  hours. 
With this adjustment, the thermostat automati-
cally returns to Day mode 8 hours after being 
switched to the Night mode.
For  example,  if  you  want  a  night  temperature 
lower  than  the  day  temperature,  both  Day/
Night modes set points will first have to be set 
at  the  desired  temperatures.  Before  bedtime, 
the  Night  mode  temperature  set  point  will  be 
activated  by  switching  manually  to  the  Night 
mode. The timer is set for the duration of the 
night. The thermostat will automatically return 
to the Day mode at the end of the night, and 
the Day mode temperature set point, which is 
higher, will become effective at this time.

+

-

+

-

+

-

+

-

Summary of Contents for STE403NP

Page 1: ...INSSTE403NP1010 STE403NP Electronic thermostat User s guide www stelpro com For further information or to consult this guide online please visit our Web site ...

Page 2: ...lectric baseboards convectors or aerocon vectors It keeps the temperature of a room at the requested set point with a high degree of accuracy This product is designed for instal lations with electrical current with a resistive load ranging from 1 2 A to 16 7 A 400 to 5750 W at 347 VAC This thermostat is not compatible with the following installations electrical current higher than 16 7 A with a re...

Page 3: ... or in front of an air outlet close to concealed ducts or a chimney and in a location with poor air flow e g behind a door or with frequent air draft conditions e g head of stairs Thermostat mounting and connection 1 Cut off power supply on lead wires at the electrical panel in order to avoid any risk of electric shock 2 Ensure that the air vents of the thermostat are clean and clear of any obstru...

Page 4: ...on Important you must activate the Fan mode when the heating unit is equipped with a fan failure of the heating unit could occur if not doing so 4 Using a screwdriver loosen the screw re taining the mounting base and front part of the thermostat Remove the front part of the thermostat from the mounting base by tilting it upward 5 Align and secure the mounting base to the connection box using the t...

Page 5: ...0 3 Operation Ambient temperature Timer Modes Frost free Day Night Fan Automatic Heating power used indicator Temperature set point Button to decrease set point timer Button to increase set point timer Set point lock ...

Page 6: ...ode to the other the system will automatically use the tempera ture set point corresponding to the Day Night mode selected The standard factory set point adjustment is 21 C for the Day mode and 18 C for the Night mode The current Day Night mode selection is indi cated on the display by the Sun or Moon icon In order to manually switch from one mode to the other simulta neously press down the two bu...

Page 7: ... thermostat is in the Day mode you must manually return to the Night mode If you want to automatically return to the Night mode the Automatic mode must be selected Automatic mode The Automatic mode which is associated to the Night mode timer allows alternating be tween the Day Night modes and the two cor responding set points over a 24 hour period Once activated this mode allows an automatic retur...

Page 8: ...n the button NOTE If you set the timer to any value exceeding 23 hours it will be impossible to activate the Automatic mode and if it was activated the Automatic mode will be deactivated 3 Activate the Automatic mode by simultane ously pressing down the two buttons for at least 3 seconds The Automatic mode icon will appear If the Automatic mode was al ready activated the same procedure should be u...

Page 9: ... or Fahrenheit symbol will be displayed 3 When the adjustment is completed release the buttons and wait for 5 seconds to exit the adjustment function Fan mode When the thermostat is used to control a heat ing system equipped with a fan the Fan mode MUST be activated This mode prevents the system to continuously start and stop which could cause fan failure The Fan mode is by default deactivated at ...

Page 10: ... to unlock the thermostat 5 While the Lock icon is blinking simultane ously press down the two buttons for more than 10 seconds until the Lock icon disap pears 6 Release the buttons The thermostat is now unlocked NOTE If the thermostat isn t unlocked within 5 minutes after the restoration of the power supply the Lock icon will stop to blink and it will be impossible to unlock the thermostat unless...

Page 11: ...eating unit has a switch If so ensure that this switch is turned on The display turns off a few minutes and then turns on again The thermal protection of the heating unit has opened due to overheating Check if the heating unit is in good condition of operation and that clearance around the appliance is according to the manufacturer s specifications The display has low contrast when heating is on T...

Page 12: ... to the factory repair or the replacement of the unit and does not cover the cost of disconnection trans port and installation Customer service Stelpro Design inc 1041 Parent Street St Bruno Quebec Canada J3V 6L7 E mail contact stelpro com Web site www stelpro com 5 Technical specifications Supply voltage 120 to 347 VAC 50 60 Hz Minimum electrical current with a resistive load 1 2 A 400 W 347 VAC ...