25
TECHNICAL DATA
Nr. of tubes
16
24
28
36
Height (mm)
775
1181
1411
1763
Length (mm)
585
495
585
495
585
495
585
Output (W)
1350
1550
1650
1650
1850
1950
1950
Article nr.
0184B0002
0184B0004
0184B0005
0184B0010
0184B0011
0184B0007
0184B0008
Voltage: 220-240V AC 50Hz
Class II - IPX4
Heating body in steel
Heating cartridge with integrated thermal limiter and thermal fuse.
Blower with 950W PTC heat element.
Reference (s) of the model:
0184B0002, 0184B0004, 0184B0005, 0184B0007, 0184B0008, 0184B0010, 0184B0011
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat output/room temperature control
Nominal heat output
Pnom
1.35 / 1.55 / 1.65
1.85 / 1.95
kW
single stage heat output, no room
temperature control
No
Minimum heat output
(indicative)
Pmin
N.A.
kW
two or more manual stages, no
room temperature control
No
Maximum heat output
Pmax,c
1.35 / 1.55 / 1.65
1.85 / 1.95
kW
with mechanic thermostat room
temperature control
No
Auxiliary electricity consumption
with electronic room temperature
control
No
At nominal heat output
Elmax
None
kW
with electronic room temperature
control plus day timer
No
At minimum heat output
Elmin
None
kW
with electronic room temperature
control plus week timer
Yes
In standby mode
ElSB
<0.001
kW
Other control options
room temperature control, with
presence detection
No
room temperature control, with
open window detection
Yes
with distance control option
No
with adaptive start control
Yes
with working time limitation
No
with black bulb sensor
No
Contact details: Stelrad Radiator Group, Welvaartstraat 14 bus 6, B-2200 Herentals
EMC
Low voltage
RoHS
EN55014-1
EN60335-1
EN50581
EN55014-2
EN60335-2-30
EN61000-3-2
EN60335-2-43
EN61000-3-3
EN62233
Standards:
Summary of Contents for E-VENTO 0184B0002