-7-
5.0 Maintenance
5.1 Maintenance
The lifetime of the compressor unit depends on the maintenance carried out. There-
fore check regularly oil level, belt tension and suction filter, and keep compressor
block and motor clean. (Especially oleaginous dust on ribs reduces cooling).
Oil:
Change oil after app. 50 operating hours and thereafter every 900 operating
hours, however, as a minimum every 6 months. Compressor unit to be warm after
operation when draining/re-filling oil.
Check oil-level glass. Level: ½ full oil-level glass.
Belt tension:
Check after app. 20 operating hours initial tensions of belt as follows:
press with a power of 40-50 N (4-5 kp) downwards on each belt on middle between
flywheel and belt pulley. Belt must be pushed app. 10 mm downwards. Tighten up if
necessary.
Drainage of water:
It is likewise important that air receiver is drained of water every
2
weeks. Water must be removed in a legal way. (Draining off at bottom of air re-
ceiver).
Filter:
Depending on surroundings of compressor the filter cartridge in suction filter
must be changed regularly.
5.2 Oil type
STENHØJ KOMPRESSOR A/S recommend that you use
STENHØJ RCS 68
which
is a fully synthetic compressor oil. Order
STENHØJ OIL
1L. no. 341705.
5.3 Environmental demands
Do no pour oil directly on soil when having changed it. Contact local authorities ad-
ministration to get information on depositing.
Summary of Contents for T63514
Page 14: ... 14 8 2 Drawing for compressorblock type PL50 ...
Page 16: ... 16 8 3 Drawing for compressorblock type PL75 ...
Page 19: ... 19 8 4 Drawing for compressorblock type PL100 ...
Page 21: ... 21 8 5 Drawing for compressorblock type TE50 ...
Page 24: ... 24 8 6 Drawing for compressorblock type TE75 ...
Page 27: ... 27 8 7 Drawing for compressorblock type TE100 ...
Page 30: ... 30 8 8 Drawing for compressorblock type PE 50B ...