SteppIR Antennas 40m - 30m Dipole Kit
14
Install the Element Housing Unit (EHU):
Warning: (For a retrofit installation only)
Mount the new 40m - 30m driven element hous-
ing unit (EHU) in the SAME orientation as the old unit that you removed. Also
refer to Drawing 2 - 4 or 6.
•
Install the driven element housing unit onto the element bracket with bolts in
holes 1 through 7 (Drawing 10) and tighten. Use the seven (7) new 10-32
Nylok nuts and the existing screws.
(For a retrofit installation only)
hole # 7 will
need to be drilled through the aluminum element bracket (with a # 6 or a 13/64”
bit) before the bolt can be installed and tightened.
•
If the mounting holes in the new EHU do not line up with the holes in the element
mounting bracket you may need to loosen the two horizontal bolts [Picture 1
(Driven Bracket)] that secure the element mounting bracket to the boom and
then insert the screws in the EHU and tighten. Be sure to retighten the two hori-
zontal bolts when you are finished mounting the EHU.
•
The remaining three bolts do not pass through the aluminum element plate but be
sure they are tight also.
Note: With a retrofit installation this is the point where you want to reconnect
the control cable and run the “Test Motors” procedure outlined in the
main antenna installation manual to verify the wiring is correct and eve-
rything is functioning before final assembly.
Installing CPVC Liner Tubes:
Locate:
•
Four pieces of 3/4” CPVC liner extension tubing
(picture 4 & 5 only has 2 shown in picture) with
CPVC coupling installed, two poles for each side.
•
One CPVC glue kit
•
One or more good assistants
•
Using the supplied glue and cotton tips, apply the
glue onto any area where there is a CPVC connection. Be sure and place the glue
onto the outside of the CPVC tubing and NOT ON THE INSIDE OF THE COU-
PLER. Then slide the coupler onto the CPVC so that none of the glue goes onto the
inside of the CPVC, this would cause a potential blockage inside the tube.
•
Glue the two CPVC sections together so that the 43.5” section can be glued to the
element housing and the 49” will slide into the Fiberglas Telescoping Pole first. Let
it dry for ten minutes.
•
Repeat this process for the other side.
Picture 4