37
2112 116TH AVE NE SUITE 1-5, BELLEVUE WA, 98004 WWW.STEPPIR.COM TEL: (425)-453-1910 FAX: (425)-462-4415
Ensure all of the control cables are taped and secured to the boom.
If you have purchased the connector box option refer to the connector box manual for correct
wiring.
Apply a thin coat of connector protector to the the exposed wires.
Follow
Figure 23
for correct wiring. Also note that the ground wires are all connected togeth-
er and use a single position terminal strip that is provided.
Be careful not to over tighten the screws on the terminal housings.
Once all the control cables from the EHU’s and control cable are correctly wired, fit the termi-
nal strip into the terminal housing that has been mounted close to the mast plate.
To fit the terminals into the terminal housing place the two 8 position terminals parallel to
each other and slide them into the terminal housing.
Make a couple of wraps of electrical tape around the control cable bundle where it will pass
through the notch in the threaded plug. This will help to protect the cable sheath from the
threads in the tube.
Guide the control cable into the drain hole on the black screw on cap.
Tighten the cap onto the terminal housing, CAUTION Be careful not to cut or damage the
control cable as you tighten the terminal housing cap.
Figure 23
WIRING DIAGRAM FOR DB 36
Truss Eyebolt Assembly