HLSB-36PCI2 User's Manual
1-6
1.6 The access without driver software
When you directly access to HLSB-36PCI2 without StepTechnica's driver software, note the following point.
Always use 32bit access to access to HLSB-36PCI2. At that time, lower 16 bit data will be used and upper 16 bit
will be unused.
For this reason, address to access needs to be specified 2 times longer than memory map mentioned above.
For example, in order to read 200H address of MKY36#1, make the lower 16bit in 400H of HLSB-36PCI2 obtain 2
bytes data in 200H of MKY36#1 by executing 32bit Read.
In addition, in order to write to 180H address of MKY36#2, the lower 16bit out of written 32bit data is written to
180H of MKY36#2 by 32bit Write to 1300H of HLSB-36PCI2.
This access method applies to HLSB-36PCI2 unique register.