7
CONTINUITY TESTING
1.
Slide the selector to the position.
2.
Press the
FUNC
button until the symbol appears on the screen.
3.
Put the the test tips on the component.
When the detected resistance
is less than 10 ~ 60 Ω, a 2 kHz sound (beep) is generated to indicate
continuity.
HOW TO USE
RESISTANCE MEASUREMENT
1.
Slide the selector to the position.
2.
Press the
FUNC
button until the symbol appears on the screen.
3.
Touch the component with the tips.
The reading will automatically appear on
the screen.
When measuring the SMD device on the PCB, you must disconnect the
power and discharge all the high voltage capacitors.