• The voltage in direct polarization is displayed in mV, in inverted polarization the
LCD screen will display “1”.
Range
Testing conditions
Accuracy
Direct pol. current 1mA
DC approx.
Approx. Direct polarization voltage
reading.
Inverted pol. voltage
2,8 VDC approx.
Open circuit approx.
voltage 2,8 VDC
Audible if the resistance is under
30 Ω.
Measuring audible continuity
1. Connect the red testing probe in “V/Ω” and the black testing probe in “COM”.
2 Set the knob to 200 Ω.
3. If the resistance is less than 30 Ω the meter will sound.
4. If the circuit is open, the LCD screen will display “1”, indicating over range.
5. If you use this function while the circuit is energized, the buzzer will sound to
warning you. Don´t worry about it, it won´t cause any damage.
Protection against overcharge: 250 VDC or AC rms.