13
13
6. TROUBLESHOOTING
Trouble
Solutions
The multimeter doesn´t
show measurement
• Check the 9 V battery.
• Select the required scale with the knob.
• Connect the cables correctly.
• Turn on the multimeter.
7. SPECIFICATIONS
Resistance: 200 Ω to 20 MΩ
CC voltage: 200 mV to 1000 V
CA voltage: 200 mV to 750 V
CC current: 200
μ
A to 20 A
CA current: 200
μ
A to 20 A
Screen 3 ½ digits.
Accuracy ± 0.5% CD
Full range, automatic zero, overrange and low battery
Resolution of 0.1 μA for small currents
Protection against overload and audible indicator to incorrects measurements
Power: 9Vcc
Temperature: 23º C ± 5º C
Humidity: 80%
Dimensions: 87 x 172 x 36 mm
Weight: 370 g. (including battery)
Nominal consumption: 0.131 kWh/year
Stand-by power consumption: not applicable
Product design and specifications are subject to change, without notice.