Ensure mains at the power panel are turned off before connecting power to the controller. Apply any necessary 

protection to assure that mains are not accidently turned on during the installation. 
 

1)  Make sure all the circuit breakers in the 

controller are turned off. 

 

2)  Confirm the controller being installed is designed 

for the line voltage and intended load(s).  Check 
labels, circuit breakers and fuse sizes before 
installing. 

 

3)  Connect the door switch to two terminals on TB1 

marked “DOOR”. The door switch is low voltage 
24vac. 

TB1 

– Torque 

AGW 

In. Lb. 

18-22 

3.5 

 

4)  The enclosure meets type 4 approval for water 

resistance. Use fittings that are consistent with 
the environmental rating of the enclosure. Use 
proper torque values. 

 

5)  When drilling holes, use caution as to not 

damage internal components. Use the markers 
inside the enclosure for safe drilling locations. 
Ensure that holes are not close to each other 
and away from the edge of the door to help 
prevent cracking. 

 

6)  Remove the screws that secure the inner door. 

This compartment should be opened by a 
qualified electrician only! 

 

7)  Connect BMS. BMS includes Door and/or 

watchdog. 
 

8)  Connect Bank-1 and Bank-2. Ensure that both 

banks carry relatively equal load for proper 

watchdog operation. Ensure proper circuit 
breaker and grounding wire torque 
 

9)  Connect Mains. Ensure proper circuit breaker 

and grounding wire torque 
 

10) Torque the circuit breakers CB1, CB2 & CB3. 

CB1, CB2 & CB3 - Torque 
AGW 

In. Lb. 

3 to 12 

13 to 17.5 

 

11) Torque ground bar TB2. 

TB2 

– Torque 

AGW 

In. Lb. 

4 to 6 

45 

40 

10 to 14 

35 

 

12) Close inner door and secure the screws. 

 

13) Turn on the mains at the power panel on. 

 

14) Turn on the mains in the Simple Controller. 

 

15) The RED stop light should be illuminated. 

 

16) Turn on the Bank1 and Bank2 circuit breakers. 

 

17) Close and latch the Simple Controller front door. 

 

18) Press the Green Start Button. 

 

19) The emitters should be illuminated. 

 

1)  If applicable, Connect Watchdog BMS relay to a BMS system. 

Watchdog 

– Torque 

AGW 

In. Lb. 

16-26 

1.7 

 

2)  Reset the watchdog by press and hold the reset button until the green light is constant. 

 

3)  The following conditions will send an alarm to the BMS system: 

a)  If a bank LED is Red. 
b)  Power loss. 

No LED’s are light. 

 
 

 

I

NSTALLATION

 

W

ATCHDOG

 

Summary of Contents for 8100PVAB

Page 1: ... personal injury or product and property damage WARNING Before performing maintenance ensure unit is unplugged Electrical shock can cause death CAUTIONS Never expose eyes or skin to UVC light Wear gloves face shield glasses per ANSI Z87 1 and cover all exposed skin Do not touch EmitterTM glass without gloves Damage to Emitter may result Oil from fingerprints will permanently etch glass of Emitter ...

Page 2: ...nner door This compartment should be opened by a qualified electrician only 7 Connect BMS BMS includes Door and or watchdog 8 Connect Bank 1 and Bank 2 Ensure that both banks carry relatively equal load for proper watchdog operation Ensure proper circuit breaker and grounding wire torque 9 Connect Mains Ensure proper circuit breaker and grounding wire torque 10 Torque the circuit breakers CB1 CB2 ...

Page 3: ...ns Line output fuse PN 80004125 500 Line output fuse low voltage circuit PN 80004115 1000 Door Switch Connection TB2 Ground Bar Circuit Breakers Watchdog Reset Display Watchdog connection to BMS dry contacts Door Switch Connection ...

Page 4: ...t by holding the reset button down or cycle through the menu A successful reset will be followed by a marque pattern of LED s This pattern will repeat itself 8 times Menu 1 Report Run Hours This is part of the 9 000 hour timer Hold the reset button until the green run LED starts to flash Each flash of the LED indicated that 1 000 hours has expired At 9 000 hours the end of emitter life alarm will ...

Page 5: ...________________________________________________________________________________________________________ Thank you for choosing Steril Aire 1 UVC for HVAC solution provider worldwide Please contact your local supplier or Steril Aire directly if we can provide any further information or service Call 1 818 565 1128 or visit www steril aire com Your satisfaction is very important to us The health asp...