background image

Installation and user manual

Please read carefully and keep available for later use

03/2020 Version

SR-12-108-5EN/03-2020

Système 7 sel EVO electrolyser

EVOLUTION

Stéril  r

Summary of Contents for EVOLUTION SYSTEME 7 SEL EVO

Page 1: ...Installation and user manual Please read carefully and keep available for later use 03 2020 Version SR 12 108 5EN 03 2020 Système 7 sel EVO electrolyser EVOLUTION Stéril r ...

Page 2: ...iption 10 11 2 Fitting the box 11 11 3 Box electric connection 11 12 Electrolysis side configuration 12 12 1 The box is configured depending on the installed electrode model 12 12 2 Configuration of the reverse polarity time adapted to the water hardness 12 12 3 Production percentage setting with the automatic cover open 13 12 4 Forced operation activation 13 12 5 Connecting the supplied slatted c...

Page 3: ...nts 1 set of instructions 1 1 electrolyser box with 230 Vac power cable 2 4 screws and 4 anchors to install the box 3 1 complete vessel with 2 Ø 50 mm connections 2 Ø 63 mm connections 1 deflector and 1 electrode cap 4 1 terminal cover 1 set of cable clamps and 2 caps 5 1 electrode 6 1 electrode cable 7 1 slatted cover cable Slow Mode 8 10 salt test strips 9 Electrode Number of plates Chlorine pro...

Page 4: ...en Recycling The packaging for your appliance is recyclable Participate in protecting the environment by disposing of it in the suitable recycling container Your appliance contains many recyclable materials The appliance must be disposed of in a recycling collection centre 4 Technical characteristics Packaging dimensions L 400 mm D 400 mm H 400 mm Pack weight 6 50 Kg Box dimensions L 260 mm D 150 ...

Page 5: ...gae Disinfectant agent Hypochlorous acid Sodium hypochlorite Hydrochloric acid decomposition SALT NaCl 6 Evolution SYSTÈME 7 SEL EVO electrolyser The SYSTÈME 7 SEL EVO electrolyser has had a technology upgrade Power supply adapted to the bipolar electrode 120 watts Features Electrode model configuration to limit the intensity of the current and extend electrode service life Water hardness configur...

Page 6: ...ary The electrolyser is not compatible with metal filters Do not open the electrolyser box without the manufacturer s permission The electrolyser is compatible with a liner reinforced PVC gelcoat mosaic silico marble or sprayed concrete pool surface Use salt for electrolysers compatible with the NF EN 16401 standard Recommended salt level 4 grammes per litre Turn the electrolyser off when adding s...

Page 7: ...swimming pool 230 Vac Caution the Stérilor cell must be installed with the connection head at the bottom Manifold Filter 8 2 Cell L installation drawing Main drain Skimmers Pump Stérilor cell To booster compressor Heat pump Filtration unit Automatic coverconnector To drains To backflow nozzles Return to the swimming pool 230 Vac Caution if the vessel is installed in the L position remove the defle...

Page 8: ... mechanical strains Maintain the vessel ends in position using suitable ties not included Positioning mark on the connections to facilitate bonding a PVC T or angle Offset connections to make it easier to align the vessel with the PVC piping Only fit the deflector if the vessel T version installation is used Unclip the deflector from the vessel if the electrode installation L version is used Posit...

Page 9: ... tightening Fit the conical cable clamp onto the cable sheath be careful of the direction Position the terminal cover Fit and manually tighten the 2 caps Gently pull the cable to lock the cable clamp If the electrode is installed in the vessel in the L position remove the deflector from the vessel Bipolar electrodes compliant with Pool Technical Directive D T P n 15 Electrode Number of plates Chlo...

Page 10: ... Auto running function Forced running function Red indicator Polarity indicators Green left polarity Orange right polarity Slatted cover indicators Green open Red closed Display screen Right side Slatted cover connector Slow Mode Switch 3 15 A timed fuse Cell cable connectors Left side ...

Page 11: ... the box to favour air flow cooling The electric connection must be made by a qualified person Cut off the power supply before any connection Provide a 6A circuit breaker coupled to the pump contact for the electrolyser connection When the filtration pump is stopped the electrolyser must also be stopped Couple the electrolyser electric connection to the filtration 11 3 Box electric connection Impo...

Page 12: ...e using the or keys Switch the box off again to memorise the setting 12 2 Configuration of the reverse polarity time adapted to the water hardness Your appliance has been configured for 25 f Polarity reversal every hour You must measure the hardness of your pool water The measured value will determine this setting This configuration is used to optimise the electrode service life by adapting the po...

Page 13: ...e the 24 effective hours by pressing the A key for 5 seconds 12 5 Connecting the supplied slatted cover cable Slow Mode Connector to be connected to the left side of the box marked Coupling 2 wires to strip and connect to the automatic cover contact Slow mode Caution novoltageontheautomaticcovercable VOLTAGE0Volt drycontact 12 6 Production percentage setting with the automatic cover closed This se...

Page 14: ... condition Salt level too low Check the min salt content 4 g litre Scaled electrode Check the electrode condition Clean with a suitable product Acidulor if necessary Electrode wear The electrode is at the end of its service life Replace it A17 Electrode condition Salt level too low Check the min salt content 4 g litre Electrode disconnected Check the electrode connection and the continuity of its ...

Page 15: ...d electrode cap if necessary 15 Manufacturer tips Reduce your chlorine production when you close your pool bar cover or other type of cover You can connect the slatted cover cable Slow Mode supplied with your electrolyser to a switch not powered Indicate Normal and Reduced on it This switch replaces the slatted cover contact relay The user turns the switch to the Reduced position when the pool cov...

Page 16: ...e product must be installed to trade standards in compliance with applicable standards and with the technical manual Detail of commercial guarantees from your pool professional The following cases are not covered by the guarantee Opening the box without the manufacturer s permission Defects and damage to the appliance caused by incorrect use Pool water quality must be compliant with the NF EN 1671...

Page 17: ...NTEE CARD Return a properly filled in copy no later than 15 days after commissioning the appliance to Société AS POOL STÉRILOR ZAC de la Rouvellière 72700 SPAY Retailer s stamp Purchaser s name and address Purchase date Serial number Information that must be provided for the guarantee in order to be taken into account Pool volume m 3 Water source Public network Borehole Well Rainwater Pool pH Regu...

Page 18: ...l r AS POOL contact aspool com Phone 33 0 2 43 42 39 20 Fax 33 0 2 43 42 41 53 ZAC de la Rouvelière 72700 SPAY S A S WITH AN EQUITY CAPITAL OF 300 000 SIRET 400 916 979 000034 APE CODE 2223Z FR 314 0091 6979 ...

Reviews: