17
Sample Ramp Soak Program
Segment Prompt
Function
Time (Min.)
Setpoint
o
F
1TI
1st Event
1
1SP
50
2TI
2nd Event
2
2SP
150
3TI
3rd Event
2
3SP
150
4TI
4th Event
2
4SP
100
5TI
5th Event
1
5SP
100
6TI
6th Event
2
6SP
50
7TI
Un-Used
0
7SP
Hold Last Setpoint
50
↓
Un-Used
GTI
Un-Used
0
GSP
50
END
Stay at present set pt. (gSP)
HLd
END
Turn off outputs at end of program
Oof
END
Repeat program at 1TI
Lop
Summary of Contents for M2B
Page 1: ... Rev A ...
Page 49: ...48 ...