Just like the spa foundation, the COVANA also requires a solid foundation. The area that the
COVANA sits on must be able to support at least 600lbs (300kg) and must be level.
Note: Damage caused by inadequate or improper foundation support is not covered by
the COVANA warranty. It is the responsibility of the owner to provide proper foundation.
Foundation recommendation:
1.
Engineered wood deck
2.
Concrete Pad - 4” (100mm) thickness
3.
Each of the 4 posts on the Covana must be properly anchored to the foundation using
at least one of the pre-drilled holes located on the foot of each post.
Use a 1/4” (6mm) concrete anchor for concrete pads or a 1/4” (6mm) lag bolt for
wood foundations a minimum of 1-1/4” (30mm) long
1.
The COVANA requires a dedicated 115V (230V*) permanently connected (hard wired)
power supply.
2.
The COVANA motor has a dedicated connection for 115V (230V*), please see enclosed
connection diagram.
3.
The COVANA must be installed in accordance to and comply to any local codes and
regulations. All wiring should be installed by a qualified electrician
4.
Wire and conduit should be sized as per local codes and regulations.
The electrical circuit for the COVANA
must include a suitable ground fault interrupter
(GFCI)
as required to comply to codes and regulations.
Required Voltage:
115V (230V*) (1 hot, 1 neutral, 1 ground)
Required GFCI Breaker:
15A (10A*) single-pole GFCI breaker, not included
Max COVANA current draw:
12 (6*) Amps
* For European customers only.
PREPARING A PROPER FOUNDATION
COVANA ELECTRICAL REQUIREMENTS
Summary of Contents for COVANA
Page 2: ...202558 COVANA III Revision 5 2 La version française du manuel débute à la page 21 FRANÇAIS ...
Page 8: ...202558 COVANA III Revision 5 8 FRAME DIMENSIONS AND FOOTPRINT ...
Page 12: ...202558 COVANA III Revision 5 12 Wiring Schematic Diagram 120VAC 60Hz Operator North America ...
Page 13: ...202558 COVANA III Revision 5 13 Wiring Schematic Diagram 220VAC 50Hz Operator Europe Only ...