XC880A OWNERS MANUAL
4.7.3 Loading Configurations
Follow the steps below to load a configuration from memory.
1. Press ‘SHIFT’ followed by the ‘2’ key. The display reads
‘STORE CONFIG?’. Press the ‘0’ key.
2. The XC880A prompts with ‘LOAD CONFIG?’. Press ‘1’.
3. The user is prompted to ‘SELECT A CONFIG’. Press the
‘SCALE SELECT’ key until the desired configuration name is
displayed.
4. Press ‘ENTER’ to load the settings, and return to the previous
state. The parameters will now be set to reflect the new
configuration. (See table below for details).
Table 4.7.3 Preset Configuration Settings
Name
→
Standard
Metric
Std. Check
Weigh
Fast Check
Weigh
Audible
Check
Weigh
↓
Parameter
↓
Averaging
LOW
LOW
LOW
OFF
LOW
Digital Filter
MED
MED
LOW
LOW
LOW
Motion Band
0.5
0.5
1.0
1.0
1.0
Zero Tracking
OFF
OFF
ON
ON
ON
Fast Stepping
ON
ON
ON
ON
ON
Display Units
LBS.
KGS.
LBS.
LBS
LBS
SP Mode
OFF
OFF
CMP
CMP
CMP
SP Data
N/A
N/A
NET
NET
NET
SP Units
N/A
N/A
LBS
LBS
LBS
Audible
Check Weigh
N/A
N/A
NO
NO
YES
Prompt For
Tare
OFF
OFF
OFF
OFF
OFF
Repeat
Prompting
ON
ON
ON
ON
ON
Prompt To
Count
ON
ON
ON
ON
ON
23