Technical Information
Fixture*:
Basin area:
Bathing well
40
″
(1016 mm) x 27
″
(686 mm)
Top area
52
″
(1321 mm) x 35
″
(889 mm)
To overflow:
Water depth
11
″
(279 mm)
Capacity
55 gal (208.2 L)
* Approximate measurements for comparison only.
Pump:
V
Hz
A
1-speed
120
60
7
Model
Door width
Door maximum
height
76111110
76111120
58-1/2
″
(1486 mm)
*NA
* Varies with alternative walls.
Required Electrical Service
Dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump
120 V, 15 A, 60 Hz
Installation Notes
Install this product according to the installation guide.
Pump is supplied with a grounding type plug-in cord. Locate
the outlet behind the whirlpool, and within 24
″
(610 mm) of
the pump.
Do not disassemble the pump or piping as this could void the
warranty.
Size the drain cutout to fit the drain assembly that will be
used.
End stud positioning is critical.
Studs should be positioned roughly as shown.
3-1/2"
(89 mm)
30" (762 mm)
3-1/8" (79 mm)
Overflow Detail
1-1/2"
(38 mm)
43-1/2"
(1105 mm)
24-1/2"
(622 mm)
8-3/4"
(222 mm)
8"
(203 mm)
3"
(76 mm)
16"
(406 mm)
60"
(1524 mm)
19"
(483 mm)
20"
(508 mm)
42"
(1067 mm)
16"
(406 mm)
14"
(356 mm)
6" (152 mm)
(Typical)
43-1/2"
(1105 mm)
Ø 2" (51 mm) Drain
8-3/4"
(222 mm)
60-1/8" (1527 mm) Min
60-1/4" (1530 mm) Max
17-1/4"
(438 mm)
Drain Cutout
4"
(102 mm)
Pump
Motor
Location
Recommended Support Clip
Location (4 Total)
Product Diagram
ENSEMBLE
TM
ENSEMBLE
TM
42
″
(1067 mm) WHIRLPOOL BATH
Page 2 of 2
1021378-4-
H