BJ5-620 Maintenance 37
of
73
Lubrication Intervals
Shift Operation
Replace Lubricant
Check
One shift operation
Every 18 months
Monthly
Two shift operation
Every 9 months
Monthly
Three shift operation
Every 6 months
Monthly
Check lubricant quality
You can judge whether the lubricant needs to be replaced by checking for the following
features:
•
Change in consistency
•
Discoloration
•
Degree of soiling
Replacing or Refilling Lubricant
•
Fill the bearings uniformly with grease until all operating surfaces are well greased.
•
For the rotor bearings, a lubricant quantity of one third to a maximum of half of the
bearing volume per bearing is required. If too much grease is used, the lubricant will
become unusable due to excessive temperature.
•
Only one type of grease may be used, mixing different types of grease is prohibited.
The bearings have been filled at the factory with lithium base saponification roller
bearing grease F3.
•
Refer to the “List of Lubricants” in this section for recommended bearing grease.
Summary of Contents for SXS 1500
Page 60: ...BJ5 620 Appendix 60 of 73 A 2 Technical Specifications...
Page 62: ...BJ5 620 Appendix 62 of 73 Bed knife fixing...
Page 63: ...BJ5 620 Appendix 63 of 73 Rotor Assembly...
Page 64: ...BJ5 620 Appendix 64 of 73 Drive...
Page 65: ...BJ5 620 Appendix 65 of 73 Ram...