background image

InstallatIon and maIntenance guIde

∙ 

BEHIND MIRROR TOUCH FREE SOAP DISPENSER

∙ 

BEHIND MIRROR TOUCH FREE FOAM SOAP DISPENSER

SOAP DISPENSER

FOAM SOAP DISPENSER

Summary of Contents for 280200

Page 1: ...Installation and maintenance guide BEHIND MIRROR TOUCH FREE SOAP DISPENSER BEHIND MIRROR TOUCH FREE Foam SOAP DISPENSER SOAP DISPENSER Foam SOAP DISPENSER ...

Page 2: ...00 cPs Standard discharge BTM Soap dispenser B E 1 4cc customizable by optional remote control Standard discharge BTM Foam E Varies according to viscosity and soap consis tency Sensor range 30 100 mm 10 mm 1 18 3 94 customiz able by optional remote control 1 TECHNICAL DATA 2 PRE INSTALLATION INFORMATION 3 PACK CONTENTS 4 5 INSTALLATION 6 FILLING THE SOAP TANK 7 REMOTE CONTROL FUNCTIONS LIQUID SOAP...

Page 3: ...ump valve causing strain and damage Stern soap dispensers are suitable for use with any generic liquid soap of the correct viscosity and pH The pH level of all soap used in Stern soap dispensers should be between 6 5 to 8 5 Lower levels will cause corrosion to the metal dispenser and even the rubber and plastic components Higher pH levels will cause swelling to rubber parts and degradation of plas...

Page 4: ...cts connectors are not connected properly the pump will work continuously 1 FROM THE SOAP DISPENSER TO THE BATTERY BOX OBSERVE POLARITY A For battery versions Insert six 6 D size alkaline batteries into the battery box Be sure to observe polarity configuration Install the battery box next to the BTM unit Connect the battery connector Ensure adequate clearance to allow removal of the top cover and ...

Page 5: ... out of the recommended range too close or too far The remote control can be used to adjust the following functions 1 SOAP QUANTITY The 1 4 drop keys allow the user to choose the desired soap quantity 4 2 1 to 2 3 cc 3 1 6 to 1 9 cc 2 1 2 to 1 6 cc 1 0 7 to 0 9cc Indication continuous blinking of the light in the sensor eye 2 3 1 4 2 ADJ This function resets the sensor back to factory settings Ind...

Page 6: ...ntity by increasing the dispensing time Press the button to decrease it Indication continuous blinking blue light in the sensor eye 2 AIR QUANTITY To improve soap consistency foamability change the amount air to be mixed Press the sign on the AIR button to increase the air quantity and the to decrease it Indication 2 blinks of the blue light in the sensor eye 3 RES This function resets the sensor ...

Page 7: ...caused by the clogged filter The filter can be cleaned as follows 1 Unscrew the quick connection fitting from the top of the foam compressor and pull out the filter housing 2 Remove the filter from the housing and wash it under running water 3 Reassemble the parts Clean the soap tank Clean out the tank prior to refill by flushing warm water through the hoses and pump until clean water is released ...

Page 8: ... sensor For part numbers see spare parts list Damaged sensor Illustration Solution Cause Investigation Indication O RING VISIBLE NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBLE CONNECTED PROPERLY The connector should be inserted fully until white o ring is not visible Remove the o ring if necessary AUX connector not fully inserted Continuous discharge from the nozzle False activation Soap Foam...

Page 9: ...o Stern Engineering Ltd with all warranty claims Stern Engineering Ltd is not responsible for labor charges installation or other incidental or consequential costs other than those noted above In no event shall the liability of Stern Engineering Ltd exceed the purchase price of the product If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumbing Contractor Pl...

Page 10: ...16 17 ...

Page 11: ...USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com ...

Reviews: