8
9
DETECTION RANGE:
This faucet was supplied with a self adjusting
sensor. The ideal detection range for the specific location will be set
automatically.
Only if necessary, use the remote control to adjust the sensor range
as follows:
Press the RANGE button. Wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the range and – to
reduce it. Every push will increase or decrease one level.
Note: Once you have changed the detection range with the remote control, the
distance will be remembered by the sensor, even if the power source is disconnected.
To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJUSTMENT MODE: Check that no objects
are in front of the sensor. Press the ADJ button. Once a quick flashing
of the LED of the sensor eye is perceived, remove your hand holding
the remote control and move away from the sensor area. The ideal
sensor range for the specific location will be set automatically.
Once the self adjustment has taken place, the solenoid valve will be
opened and closed for 1 second as an indication that the ideal sensor
range was set and the product is ready for use.
SECURITY TIME: The Security time, prevents continuous running
of water due to reflections or vandalism. By default, if the sensor
is covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must be
removed.
Press the SEC button. Wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the security time
and – to reduce it.
DELAY IN TIME: It is recommended to change the delay in time for flush
valves for urinals or toilets only.
If required, the delay in time can also be modified in faucets as
follows:
Press the IN button. Wait until a quick flashing of the LED in the sensor
eye is perceived. Then, press + to increase the delay in time and – to
reduce it.
DELAY OUT TIME: This button allows modifying the water flow time
after the user removes his hands from the faucet. A delay out time
close to 0 will save more water. An increased delay out time will make
the user experience more comfortable.
If required, the delay out time can be modified as follows:
Press the OUT button. Wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the delay out time
and – to reduce it.
24 HOUR HYGIENE FLUSH: This model includes a 24 hours hygiene flush
which is disabled. To activate the hygiene flush, press the clock button.
Wait until a quick flashing of the LED in the sensor eye is perceived.
Then press + to activate the hygiene flush. To disable it again, press – to
deactivate it.
COMFORT FLUSH: If your model includes a Comfort flush setting, it can
be activated by pressing the flush button.
When the button is pressed, one blink of the LED in the sensor eye is
perceived. The pre-programmed flush cycle will take place then.
The Comfort flush cannot be interrupted or deactivated by pressing any
button until it is over.
TEMPORARY OFF FUNCTION: This function is ideal to perform any kind
of activity in front of the sensor without operating the system (for
example, cleaning).
The faucet will remain shut for 1 minute when this button is pressed
once. To cancel this function and to return to normal operation press
the On/Off button again or wait 1 minute.
RESET BUTTON: This function restores all the factory settings except
for the sensor range. If required, press the Reset button and without
releasing it, press the + button once.
NOTE:
To enter the self adjusting mode, use the ADJ button. To change the sensor
range, use the RANGE button.
SETTINGS ADJUSTMENT
SETTINGS ADJUSTMENT