INsTallaTIoN

EXTrEmE cs DPE/DP b

SteP 2 – CoNNeCtING tHe wAter SUPPLy

∙ remove the plastic tip that is inserted in the end    

   of the black flexible tube.

∙ Connect the dual power box to the water supply    

    lines.

∙ Connect the black flexible tube to the quick 

    connector on the top of the dual power box.

∙ Place battery into the Dual Power input box.

SteP 3 – CoNNeCtING tHe Power SoUrCe

1

Turn on the central water supply. Check for leaks. 
Remove the protective sticker from the sensor.

2

Connect the power source.

3

Once the power source is connected, 

wait  15 seconds to allow the system 

to set the ideal sensor range. A LED 

will flash continously to indicate this 

adjustment period. The solenoid valve 

will open for 1 second to indicate that 

the ideal sensor range was set.

15 

SECONDS

2

If the automatically adjusted sensor range is not satisfactory to your purposes, 

please refer to the section entitled “Settings adjustment”.

SteP 1 – INStALLING tHe FAUCet 

1

shut off the water supply.

2

Cut an adequate sized hole in the wall for the dimensions of the faucet 

base (see Technical Data).

3

Install the faucet base firmly to the 

roughing wall.

4

Attach the temporary protective cover 

over the faucet base.

NoTE

: Make sure that the corrugated tube outlet remains outside of the wall 

during tiling. Access is needed after the completion fo the wall.

5

Once the electrical, plumbing and tile work is complete cut off the 

temporary faucet base cover. Then slide the rosette on the base of the 

faucet.

6

Pass the four pin connector and the black flexible tube (connected to the 

faucet head) through the base of the faucet until they can be accessed 

from the opposite side of the corrugated green tube.

7

Place the faucet on the base and secure it with the set screw on the bottom.

Summary of Contents for Extreme CS B

Page 1: ...1 1 Installation and maintenance guide extreme CS WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER Extreme CS B Extreme CS E Extreme CS DP B Extreme CS DP E ...

Page 2: ...hout notice to discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular p...

Page 3: ...ual power input box with inlet nipple and filter 1 x Transformer exterme cs DP Pack contents E VERSIONS 1x Dual power input box with inlet nipple and filter 1 x Transformer 1 x Spout and attachments incl electronic unit 1 x Wall rosette 1 x Elbow connection with corrugated tube 1 x Secure panel 4 x Screws and anchors 1 x Dual power input box with inlet nipple and filter ...

Page 4: ... applicable codes and regulations Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol acid abrasives or the like Use of any prohibited cleaning or maintenance products or substances could damage the surface of the faucet For surface cleaning use ONLY soap and water then wipe dry with clean cloth or towel When cleaning bathroom tile the fauc...

Page 5: ...NDS 2 If the automatically adjusted sensor range is not satisfactory to your purposes please refer to the section entitled Settings adjustment STEP 1 INSTALLING THE FAUCET 1 Shut off the water supply 2 Cut an adequate sized hole in the wall for the dimensions of the faucet base see Technical Data 3 Install the faucet base firmly to the roughing wall 4 Attach the temporary protective cover over the...

Page 6: ...ntil a quick flashing of the LED in the sensor eye is perceived Then press to increase the range and to reduce it Every push will increase or decrease one level Note Once you have changed the detection range with the remote control the distance will be remembered by the sensor even if the power source is disconnected To get back to the self adjustment mode use the ADJ button only Entrance to the s...

Page 7: ...e it Delay OUT time This button allows modifying the water flow time after the user removes his hands from the faucet A delay out time close to 0 will save more water An increased delay out time will make the user experience more comfortable If required the delay out time can be modified as follows Press the OUT button Wait until a quick flashing of the LED in the sensor eye is perceived Then pres...

Page 8: ...put box using the Allen key provided Remove the old battery and replace it with a new 9V battery Lithium battery is recommended Close the box lid and tighten it with the screw Important Spent batteries should not be disposed of with normal household waste Contact your local authority for information on waste disposal and recycling Spare Parts 10 Pack Sensor Kit 07220412 10 Pack Solenoid valve kit ...

Page 9: ...r Filter or aerator is clogged Water flow diminished Troubleshooting Security Mode If the sensor is covered for more than 90 sec the faucet will automatically shut off water flow To return to normal operation remove any blockage to re establish operation Y Stern Engineering Ltd warrants that its electronic products will be free of defects in material and workmanship during normal use for two years...

Page 10: ......

Page 11: ...777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com 12 19 01500329 B ...

Reviews: