background image

XRLED

 1843 CONVERSION KIT

6/14 STERNBERG LIGHTING. ALL RIGHTS RESERVED. PRINTED IN THE USA.

800-621-3376

555 Lawrence Ave., Roselle, IL 60172

info@sternberglighting.com

www.sternberglighting.com

INSTALLATION INSTRUCTIONS

WARNING:

  TO AVOID FIRE, SHOCK OR DEATH, TURN OFF AND LOCKOUT POWER BEFORE PERFORMING ANY MAINTENANCE.

CAUTION:

  

THIS FIXTURE MUST BE WIRED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL 
CODES. PROPER GROUNDING IS REQUIRED. ALL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN.

STEP

 5

STEP

 6

STEP

 7

Lean the bracket for-

ward toward the fit-

ter opening to allow 

the locking tab to 

enter the right side 

of the fitter where 

the roof is lower.  

Slide the bracket to 

the left and twist to 

engage the driver 

against the front 

left wall and tighten 

the thumb screw to 

restrict movement of 

the assembly. 

Remove the hex nut from the stud in the center of the roof.  Slide the 

LED bracket assembly over the stud and tighten the hex nut in place.  

Align the pointer labelled “STREET” (see arrow) so that it will face the 

street when the fixture is reassembled. Apply silicone sealant around 

hex nut.

Align the mounting studs on the bracket with the large, round outer slots on the LED assembly and slide into place.  (See note.)  

Secure assembly with lockwashers and nuts provided. 

Note:

 If backlight shields are present on the LED boards, align the LED module to the bracket pointer as shown.

Street Side / Target Area

Backlight 
Shield

(Note orientation of Backlight Shields

House Side

Reviews: