INSTALLATION INSTRUCTIONS

WARNING:

  TO AVOID FIRE, SHOCK OR DEATH, TURN OFF AND LOCKOUT POWER BEFORE PERFORMING ANY MAINTENANCE.

CAUTION:

  

THIS FIXTURE MUST BE WIRED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL 
CODES. PROPER GROUNDING IS REQUIRED. ALL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN.

 

STEP

 8

STEP

 9B

STEP

 9A

If lead mounting clips are not present, 

remove the screws on the inner cage 

frame and use them to attach the 

supplied lead mounting clips. Run 

the LED Module lead down the cage 

frame, bending the mounting clips 

around the lead to secure it. Run the 

lead into the driver chamber. Remove 

the backing from the supplied adhe-

sive mounting clip and attach it to the 

fitter top. Place lead inside the clip to 

secure the lead to the fitter top. Run 

the lead into the driver chamber.

Connect the fixture leads to the appropriate 

lever nut connector. The black lead should be 

connected to the open port of the two position 

connector with the black output lead from the 

driver. The red lead should be connected to 

the two position connector with the red output 

lead from the driver. See wiring diagram. 
Connect supply lines. Reattach fitter door. 

Close and secure roof.

For 2100mA driver with Synjet only

(For units without a Synjet, proceed to 9b) 

Connect the LED module leads to the appropriate lever nut connector. The black lead 

should be connected to the open port of the two position connector with the black 

output lead from the driver. The red lead should be connected to the two position con-

nector with the red output lead from the driver. See wiring diagram. Connect red and 

black Synjet leads per wiring diagram to the two position connectors labelled “Synjet 

Only”. Red to red. Black to black. Insert the blue and purple leads into supplied two 

position connector per wiring diagram and close cam levers. Connect supply lines. 

Reattach fitter door. Close and secure roof.

Wiring Schematic (No Synjet)